| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/02/2010 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 08/02/2010 | JASON GREEN | ENGINEERING | REVIEW | Approved | |
| 08/02/2010 | ERIC NEWCOMB | ADA | REVIEW | Passed | |
| 08/02/2010 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. SHEET A-4; ELEVATIONS: THERE ARE SEVERAL ARROWS WITHOUT REFERENCE TO VERBIAGE. VERIFY. 2. SHEET A-4; ELEVATIONS: THE REQUIREMENTS OF THE CITY OF TUCSON REQUIRE A MINIMUM OF 3/32" LETTERING HEIGHT. REVISE. 3. SHEET A-0; BUILDING CODE DATA: THE ACCESSIBILITY CODE USED FOR THIS PROJECT SHOULD BE ICC/ANSI A117.1-2003, NOT ADAAG. |
| 08/02/2010 | ERIC NEWCOMB | ZONING HC | REVIEW | Denied | 1. SEE BUILDING COMMENTS. |
| 08/02/2010 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 08/03/2010 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | Ventilation for restrooms in public spaces requires a minimum of 75 CFM of mechanical exhaust per water closet or urinal. Revise your calculations and balance accordingly. Reference: Table 403.3, IMC 2006. |
| 08/03/2010 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Needs Review | |
| 08/03/2010 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 08/03/2010 | MARTIN BROWN | FIRE | REVIEW | Denied | 1. Notes on PG A-0 for sprinkler system need plans and permits for adding 1 head or relocating more than 5 heads. permit only for less than 5 head relocate. 2. Pg A-3 under general notes #14 door hardware is A-6. 3. Pg A-6 under door notes #5 only allowed on front main door. |
| 08/03/2010 | GERRY KOZIOL | WWM | REVIEW | Passed | |
| 08/03/2010 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/03/2010 | DELMA ROBEY | OUT TO CUSTOMER | Completed |