Permit Review Detail
Review Status: Completed
Review Details: PLANS OK TO SUBMIT - RES
Permit Number - T10CM02104
Review Name: PLANS OK TO SUBMIT - RES
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/02/2010 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | CDRC TRANSMITTAL FROM: Michael St.Paul, Planning Technician PROJECT: T10CM02104 2519 East Drachman Street SFR & detached garage TRANSMITTAL: August 2, 2010 COMMENTS: the following comments are relative to an application for a Design Development Option (DDO). This Site requires a DDO for the setback to the east property line for both the single-family residence (SFR) and the detached garage.. This site is in the R-1 Zone (LUC Section 2.3.4.2.A.1). The Development Designator is "G" (LUC Section 3.2.3.1.B) and the Perimeter Yard Indicator AA (LUC Section 3.2.6.4). The minimum setback to the east property line is the greater of six feet or two-thirds the height of the structure's wall facing the property line (LUC Section 3.2.6.4). The height of the proposed SFR is fifteen (15) feet, six (6) inches. The height of the proposed detached garage is eleven (11) feet, six (6) inches. The minimum setback to the east property line for the SFR is ten (10) feet, four (4) inches and seven (7) feet, eight (8) inches for the garage (LUC Section 3.2.6.4). The proposed setback for the SFR is six (6) feet, four (4) inches. The proposed setback for the garage is six (6) feet. |
| 08/02/2010 | MICHAEL ST. PAUL | NPPO | REVIEW | Passed | |
| 09/15/2010 | CPIERCE1 | ENGINEERING | REVIEW | Needs Review | |
| 09/15/2010 | CPIERCE1 | BUILDING-RESIDENTIAL | REVIEW | Denied |