Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T10CM02007
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/20/2010 | RBROWN1 | ADA | REVIEW | Passed | Not a COT owned or operated property |
| 07/21/2010 | MARTIN BROWN | FIRE | REVIEW | Denied | Please indicate on plans existing and/or proposed fire hydrant locations, and whether or not the building will contain fire sprinklers. |
| 07/27/2010 | RONALD BROWN | ZONING HC | REVIEW | Denied | 1. Please provide dimensions of accessible parking space layout. 2. Please provide a large scale detail of the required accessible parking sign including "Van Accessible" signage and show sign locations on site plan. 3. The rear emergency exit must be accessible. a. The finish floor to top of sidewalk is 2" higher. Please provide a transition as per ANSI, Section 303.3. b. The slope of the sidewalk to the Arcadia pedestrian right of way is more than 5% which classifies this as a ramp and must comply with ANSI, Section 405. c. Please redesign and provide a large scale detail showing all critical accessible elements; dimensions, slopes, handrails, landings and etc. END OF REVIEW |
| 07/29/2010 | STEVE SHIELDS | ZONING | REVIEW | Denied | PDSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: OReilly Auto Parts T10CM02007 Site Plan (1st Review) TRANSMITTAL DATE: July 29, 2010 COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for full code compliance for the entire site. 2. Provide a site plan that meets the requirements of Development Standards 2-02, 2-08, 2-09, 3-01 & 3-05 and all applicable sections of the LUC to include but not limited to; 2.5.4, 3.2.3, 3.2.6, 3.2.7, 3.2.58, 3.2.11, 3.3.4, 3.4.5. 3. Depending on how the above comments are addressed addition comments may be forth coming. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956. C:\planning\site\t10cm02007 RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Site plan. |
| 07/30/2010 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | 1. Fifty (50) percent or more of the street landscape border area must have shrubs and vegetative ground cover per LUC 3.7.2.4. The canopy tree requirement is in addition to the landscape requirements. Additional plants are required to meet coverage. 2. Indicate square footage of all landscaped areas and calculation of the percentage of vegetative coverage per DS 2-07.2.2.2.g. 3. Within a vehicular use area, one (1) canopy tree is required for each 4 motor vehicle parking spaces per LUC 3.7.2.3.A.1. 4. Key Note #1 should read: Except as otherwise provided by this Division, the area between the right-of-way line and sidewalk and the area between the sidewalk and the curb, if not covered with vegetation, shall be covered with an appropriate inorganic ground cover, such as decomposed granite. 5. Commercial Rainwater Harvesting Development Standard 10-03.0 applies to all commercial development plans submitted after June 1, 2010. Submit a Rainwater Harvesting Plan Per DS 10-30.4.2.A 6. Rainwater Harvesting plan shall include irrigation specification design and layout per DS 10-03.5.2. Including source of irrigation sleeves for driveways and sidewalks, locations of valves and sensors for drip irrigation. 7. The site plan and landscape plan must show identical site layout to avoid conflict between the two plans. Ensure that all changes to the site plan are reflected on the landscape plan. 8. Additional comments may apply. |
| 08/02/2010 | ANDREW CONNOR | NPPO | REVIEW | Approved | Exception |
| 08/10/2010 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | Revise the site drawing to include the following information: a. the location and size of the water meter b. the location of the main water lines and fire hydrants c. the location of the gas meter (if one exists or is planned) d. the size of the public sanitary sewer e. the location of the building connection to the public sewer f. the location, invert, and rim elevation of all manholes and cleanouts Reference: City of Tucson Development Standard No. 2-01.1.0 2 3.8 D and Section 103.2.3, UPC 2006. |
| 08/12/2010 | LOREN MAKUS | ENGINEERING | REVIEW | Denied | August 16, 2010 T10CM02007 T10BU01146 O'Reilly Auto Parts Site and Grading Plan Review Provide a local benchmark and basis of elevation. The temporary benchmark provided is clearly from a different project. There is a FEMA Floodplain Zone AE along Arcadia Avenue. Provide the delineation for the floodplain and water surface contours. A contour should be provided at the upstream corner of the building. The contour elevation should be in the same datum as the local benchmark. Provide adequate freeboard for the lowest floor of the proposed retail store above the adjacent floodplain elevation. Add a note to the site plan to indicate that a floodplain use permit will be required for all work within the floodplain. This includes all improvements in the right-of-way along Arcadia Avenue. Provide all of the applicable elements of the site plan development standard (DS 2-02). Since this plan is also serving as the grading plan, provide sufficient detail to complete the grading of the project. Provide construction details or specifications for sidewalks, curbs, pavement, parking blocks and other features. Remove the erosion and sediment controls from the site/grading plan. These may be included but must be separate from the site and grading plans. Add a note to indicate that all work in the right-of-way will require a separate right-of-way permit. Revise the solid waste container enclosure to provide an angle suitable for the solid waste vehicle to service the container. Also provide construction details and dimensions for the enclosure. The enclosure should provide a 10 by 10 clear area for the dumpster with bollards protecting the side and rear walls. Additional comments may be forthcoming once a complete site plan and grading plan are submitted. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/26/2010 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 08/26/2010 | SUE REEVES | REJECT SHELF | Completed |