Permit Number: T10CM01808
Parcel: 107070310

Review Status: Completed

Review Details: COMMERCIAL TI

Permit Number - T10CM01808
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/19/2010 PATRICIA GEHLEN ZONING REVIEW Approved
07/20/2010 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Approved
07/20/2010 DAVE MANN FIRE REVIEW Approved
07/20/2010 PAUL MACHADO ENGINEERING REVIEW Approved
07/21/2010 RONALD BROWN ZONING HC REVIEW Approved
07/21/2010 GERRY KOZIOL WWM REVIEW Approved
07/21/2010 RONALD BROWN BUILDING-COMMERCIAL REVIEW Approv-Cond 1. Correspondence is to be sent to LeeRay Hanly providing a list of deferred submittals for the purpose of accessing additional plan review fees.
2. Special Inspection Certificate for the approval of an/the inspector, not a Firm listing, for field welding is required for approval prior to issuance of the permit.
07/21/2010 ROBERT SHERRY WATER REVIEW Approved
07/21/2010 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. Clarify the layout and direction of flow for the building drains. The submitted model plans do not agree with the proposed tenant improvement and the site plan for the current project.
2. Revise the site drawing to show the route, cleanout locations, and the slope of the building sewers. Reference: Section 103.2.3, UPC 2006.
3. Clarify the layout of the waste piping in the new restroom. Water closet P1A appears to have a trap arm running to the stack behind water closet P1 as well as having a trap arm, vent, and drain line running north to an existing 4" drain.
4. Both urinals (P2) and the new floor drain (P9) appear to require an additional cleanout due to their circuitous drain piping; an additional clean out is required whenever the aggregate horizontal change in direction exceeds 135 degrees. Reference: Section 707.5, UPC 2006. (Two notes regarding the drain piping for these fixtures on detail 2/P4 are in error: "CONN. 2"S TO EXIST. 4" S". A 4" wall cleanout is located upstream of the junction of the new and existing drain pipes.)
07/21/2010 BETH GRANT COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Completed
07/23/2010 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Approved