Permit Number: T10CM01561
Parcel: 99999999A

Address:
1375 W AJO WY

Review Status: Completed

Review Details: COMMERCIAL-BLDG/FIRE/ZONING/ENG

Permit Number - T10CM01561
Review Name: COMMERCIAL-BLDG/FIRE/ZONING/ENG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/10/2010 DAVE MANN FIRE REVIEW Denied Fire Comments:

The site plans Sheet 11 indicate the building has fire sprinklers. the fire hydrant is just over 300 feet from the most remote point on the building.

The building plans do not show a sprinkler system. Please clarify. A small change in the hydrant location may be required.
06/16/2010 JASON GREEN ENGINEERING REVIEW Denied Provide a copy of the stamped aprroved development plan S09-081 for building plan and canopy stamp approval. The plans may be brought through as a counter walk through once the development plan package has been finalized through CDRC.
06/17/2010 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Denied 1. SHEET AB2; STRUCTURAL CALCULATIONS (BASE PLATE DESIGN): THE BASE PLATE INDICATED ON THE DRAWINGS (1 1/2"X22"X1'10") DOES NOT MATCH THE CALCULATIONS STANDARD BASE PLATE DRAWING (1 1/2"X18"X1'-6"). CLARIFY.
2. SHEET E1 (CANOPY FRAMING PLAN); STRUCTURAL CALCULATIONS (SHEET 11): THE COLUMN CALL-OUT ON THE FRAMING PLAN IS TS10X10X1/4, BUT THE CALCULATIONS LIST A TS10X10X5/16. CLARIFY.
3. STRUCTURAL CALCULATIONS: DID NOT LOCATE THE ANCHOR BOLT DESIGN AT THE COLUMNS. VERIFY.
4. GENERAL: PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS.
06/18/2010 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Approved
06/18/2010 ERIC NEWCOMB HC REVIEW Approved
06/21/2010 STEVE SHIELDS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: Quick Trip
T10CM01560 & T10CM01561
Building Plan (1st Review)

TRANSMITTAL DATE: June 21, 2010

1. The building plan has been reviewed by Zoning Review Section and matches what is shown on the approved development package. Once all other PDSD agencies have approved Zoning will approve the building and fuel canopy plans.

2. Zoning is available for an over-the-counter review once all other PDSD agencies have approved the plans. Please call or email to schedule an appointment for the review.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956

C:\planning\grading\t10cm01560.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED:

Final Status

Task End Date Reviewer's Name Type of Review Description
07/27/2010 GERARDO BONILLA OUT TO CUSTOMER Completed
07/27/2010 SUE REEVES REJECT SHELF Completed