Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T10CM01535
Parcel: 124061920

Address:
128 N FREMONT AV

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T10CM01535
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/14/2010 GERRY KOZIOL WWM REVIEW Approved
06/14/2010 CLAYTON TREVILLYAN BUILDING-RESIDENTIAL REVIEW Denied PLAN REVIEW COMMENTS
Date: 6-12-10
Activity: T10CM01535
Address: 128 N Fremont
Applicant: Jesus Maldanado

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken.

SCOPE OF REVIEW:
The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:
1. Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets.

SITE PLAN:
2. Show the location of utilities to both buildings, R106.1.1.

FLOOR PLANS:
3. Specify the size and operation of all windows.

FOUNDATION PLANS:
4. Specify the size of (or minimum size of) the landing or floor surface required at all exterior doors, R311.4.3.

STRUCTURAL PLANS:
5. Clarify the diaphragm between trusses as called for on braced wall note.
6. Provide cross references on the framing plan to page 5 for the appropriate details.
7. Provide reference on framing plan for location of header schedule.

ELEVATIONS:
8. Provide an attic space ventilation calculation and note the size and location of all attic vents needed to comply or show compliance with unvented attic space criteria, R806.2.

SECTIONS - DETAILS:
9. Provide cross section of existing building that will remain including roof framing, wall and footing construction and compliance with current energy efficiency measures.
10. Ceiling gypsum board must be either 5/8" or ½" sag resistant when applied to ceilings framed at 24" o/c, IRC table R702.3.5 footnote d.

PLUMBING PLAN:
11. The 2006 Uniform Plumbing Code and the 2006 International Plumbing Code are not interchangeable. Only one code may be used in the plumbing design. Verify all fixture unit values reflect the applicable code.
12. Provide protection of (indoor rated) equipment located outdoors, UPC 508.27.
13. Include plumbing fixtures located in the second dwelling unit on water supply schedule and calculations or show individual water meters.

MECHANICAL PLAN:
14. Clarify the HVAC system components (is it a heat pump or a gas pack?)

ELECTRICAL PLAN:
15. The light in the laundry area may not share the laundry circuit, E3603.3, 3801.8.
16. Bathroom receptacles require a 20-amp circuit, E3801.6.
17. Exterior receptacles at grade level shall be provided at both the front and back of the dwelling, E3801.7. These outlets shall be GFCI protected E3802.3.
18. At least one wall switch controlled light or outlet must be provided at all outdoor entrances or exits, E3803.3.
19. Show receptacle outlets at each kitchen counter space wider than 12" so that no point along the wall line is more than 24" from a receptacle outlet, E3801.4.1.

If you have any questions please contact:
Clayton Trevillyan
520.837.4913
Residential Plan Review

Final Status

Task End Date Reviewer's Name Type of Review Description
06/16/2010 CINDY AGUILAR OUT TO CUSTOMER Completed
06/16/2010 SUE REEVES REJECT SHELF Completed