Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T10CM01479
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/01/2010 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
06/01/2010 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
06/01/2010 | ERIC NEWCOMB | ADA | REVIEW | Passed | |
06/01/2010 | ROBERT SHERRY | WATER | REVIEW | Approved | |
06/01/2010 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
06/01/2010 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Approved | |
06/01/2010 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Each piece of equipment requiring backflow protection shall be independently protected. Reference: Sections 602.2 and 603.0, UPC 2006, as amended by the City of Tucson. 2. Provide direct connections for the two new sinks and the new indirect waste receptors. The fixtures shall be trapped and vented. Reference: Sections 304.0, 704.3, 801.2.3, 801.3, 901.0, and 1001.1, UPC 2006. 3. Indirect waste pipes from food preparation sinks, dipper wells, etc. shall be separately run to the approved indirect waste receptor. Reference: Section 801.2.3, UPC 2006. |
06/01/2010 | ERIC NEWCOMB | ZONING HC | REVIEW | Approved | |
06/02/2010 | DAVE MANN | FIRE | REVIEW | Approved | |
06/02/2010 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
06/16/2010 | CPIERCE1 | WWM | REVIEW | Needs Review | |
06/16/2010 | CPIERCE1 | ZONING | REVIEW | Needs Review |