Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T10CM01412
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/02/2010 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | The submitted dryer listing calls for a 4" diameter rigid metal exhaust duct or, if that is not possible, a 4" diameter flexible metal foil duct may be used provided the 4" diameter size can be maintained for the entire duct run. The listing does not allow for the use of any other duct sizes. Reference: Sections 304.1 and 504.6, IMC 2006. |
| 06/02/2010 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | Provide a detail of the water heater installation, including the excess pressure relief, expansion tank, and valves. Reference: Sections 103.2.3, 605.5, 608.3, and 608.7 UPC 2006 |
| 06/04/2010 | GBONILL1 | WWM | REVIEW | Needs Review |