Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T10CM01412
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
05/24/2010 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
05/24/2010 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | Provide listing information for the clothes dryer to show that the proposed 3.5"x 6" dryer exhaust duct is sized correctly. Reference: Sections 304.1 and 504.6, IMC 2006. |
05/24/2010 | ERIC NEWCOMB | ADA | REVIEW | Passed | |
05/24/2010 | ROBERT SHERRY | WATER | REVIEW | Approved | |
05/24/2010 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
05/24/2010 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Approved | |
05/24/2010 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Provide fixture descriptions for all plumbing fixtures (e.g. shampoo sink) All plumbing fixtures and fittings shall be listed or labeled by a nationally-recognized, accredited conformity assessment company (e.g. UL, ETL, UPC, etc). Reference: Sections 301.1.1 and 401.1, UPC 2006. 2. Provide the minimum plumbing facilities (e.g. drinking fountain) required by Table 2902.1 and Section 2902.2, IBC 2006, for a business occupancy. 3. Correct the water pressure loss calculations. Unless the water service piping is galvanized steel, the maximum water velocity is 8fps. The fixtures noted in the demand calculation do not appear in the suite, and the water fixture units do not appear to be from the 2006 UPC, 4. Provide pressure-absorbing devices for the water connections to appliances equipped with quick-acting or solenoid valves. Reference: Section 609.10, UPC 2006. |
05/24/2010 | DAVE MANN | FIRE | REVIEW | Approved | |
05/24/2010 | ERIC NEWCOMB | ZONING HC | REVIEW | Approved | |
05/24/2010 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
05/25/2010 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
06/02/2010 | CAGUILA1 | WWM | REVIEW | Needs Review |