Permit Number: T10CM01387
Parcel: 11103058B

Review Status: Completed

Review Details: RESUBMITTAL - SITE

Permit Number - T10CM01387
Review Name: RESUBMITTAL - SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/06/2010 RONALD BROWN HC REVIEW Denied PREVIOUS COMMENT
1. Please provide a large scale detail of the actual accessible parking LAYOUT as depicted on the Sie Plan. Generic details are not acceptable.
RESUBMITTAL COMMENT
A partial two accessible parking space is not what was requested. Please provide the entire parking space layout, all 4 spaces including the "Van Accessible" space a per your generic detail 5/A1 with an 8' wide access asile which is not shown on the actual design. Please redesign and resubmit.
END OF REVIEW
08/12/2010 STEVE SHIELDS ZONING REVIEW Denied PDSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: Tucson Lodge #4 F&AM
T10CM01387 (2nd Review)

TRANSMITTAL DATE: August 12, 2010

COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for full code compliance.

2. The following items in regards to the Development Standards Modification Request (DSMR) need to be added to the plan(s);

a. Add the following to the DSMR note, state the modifications granted, and conditions imposed.
b. The case number must be added to each sheet of the site plan, grading plan, landscape plan, in the lower right corner near the title block.

3. Once the above comment has been addressed Zoning is willing to provide and over-the-counter review. Please call or email to schedule an appointment for this review.
4. Depending on how the above comments are addressed addition comments may be forth coming.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956.

C:\planning\site\t10cm01387

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents.
08/16/2010 JASON GREEN ENGINEERING REVIEW Denied DATE: August 20, 2010
SUBJECT: 3108 E Prince Road Site and Grading Plan- 2nd Engineering Review
TO: Star Consulting
LOCATION: T13S R14E Sec28 Ward 3
REVIEWERS: Jason Green, CFM
ACTIVITY: T10CM01387 (Site Plan), T10BU00828 (Grading Plan)


SUMMARY: Engineering Division of Planning and Development Services Department has received and reviewed the site plan (T10CM01387), Grading Plan (T10BU00828), Drainage Statement (Star Consulting, 05MAY10), and Stormwater Pollution Prevention Plan (JE Fuller Hydrology & Geomorphology, Inc., 19MAY10) for the above referenced property. Engineering Division does not recommend approval of the plan sets at this time. The following item needs to be addressed:


SITE PLAN COMMENTS:

1) Restated- DS Sec.2-02.2.1.A.16: Revise the General Note on the site plan to list all of the information for the approved DSMR: Along with the Development Standard # and the date of DSMR approval the note should clearly state what was being revised and what conditions where place upon the DSMR at time of approval.


GRADING PLAN COMMENTS:

2) The grading plan (T10BU00828) will be approved with the approval of the site plan.


STORMWATER POLLUTION PREVENTION PLAN:

3) The proposed SWPPP meets the minimum requirements of the AzPDES Construction General Permit (CGP). However the SWPPP and Exhibits can not be stamped approved until approval of the grading plan. Provide both copies with resubmittal for stamp approval.


GENERAL COMMENTS:

Please provide a revised plan set that addresses the comment provided above. For expedite purposes the site/grading plan can be reviewed over the counter (PDSD Engineering Division comment only) for stamp approval once all items have been addressed. Please call to schedule an appointment when ready.

To schedule an appointment I can be reached at 837-4929.



Jason Green, CFM
Senior Engineer Associate
Engineering Division
COT Planning & Development Services
08/24/2010 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Approved
08/25/2010 ANDREW CONNOR LANDSCAPE REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
08/27/2010 CPIERCE1 OUT TO CUSTOMER Completed
08/27/2010 SUE REEVES REJECT SHELF Completed