Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
05/21/2010 | DAVE MANN | FIRE | REVIEW | Approved | |
06/03/2010 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Denied | 1. Please provide completed Special Inspection Certificates for field welding, concrete and epoxy anchors. 2. Please clarify detail 1/S310. Calculations call out a fully grouted 8" cmu wall wheras the detail shows an top 8" bond beam only. 3. Minimum font size requirement is 3/32" both upper and lower case. Sheet M1614 needs to be reworked to meet this requirement. END OF REVIEW |
06/10/2010 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | Show how the routing of the boiler condensate piping complies with the intent of Section 811.4, UPC 2006. |
06/14/2010 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Provide sizes for the hanger rods shown in detail E/MP511. Reference: Section 305.2, IMC 2006. 2. Provide additional construction information for detail B/MP511: what are the dimensions of the bracket, the u-bolts, and the wall anchors? For what size pipe does this detail apply? Reference: Sections 106.3.1 and 305.2, IMC 2006. 3. Revise detail A/MP511 to utilize a support that is suitable for the intended use. The Miro 8-DSA duct and cable tray support is limited to a maximum duct diameter of 26" according to the manufacturer. Reference: Sections 106.3.1 and 305.2, IMC 2006. |
06/17/2010 | LEERAY HANLY | ELECTRICAL-COMMERCIAL | REVIEW | Approved |