Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
05/14/2010 | SREEVES1 | ADA | REVIEW | Passed | |
05/17/2010 | DAVE MANN | FIRE | REVIEW | Approved | |
05/20/2010 | GERRY KOZIOL | WWM | REVIEW | Denied | NEED WASTEWATER 5TH FLOOR CREDIT EVALUATION FOR EXSISTING 2 TOILETS & 2 LAVS PER DRAWING |
05/21/2010 | SUE REEVES | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
05/27/2010 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. PREVIOUS COMMENT; GENERAL: ALL LETTERING MUST BE A MINIMUM OF 3/32" IN HEIGHT PER CITY OF TUCSON REQUIREMENTS (SHEETS a1.1/ACCUREX SHEET/a2.0). 2. PREVIOUS COMMENT; GENERAL: REPRINT SHEETS THAT HAVE THE TOP AND/OR RIGHT SIDE CUT OFF (SHEETS a2.0/a2.?/a4.0/a5.0). 3. PREVIOUS COMMENT; GENERAL: SHEETS a5.0/a9.0/a9.2 REQUIRE A PROFESSIONAL STAMP, SIGNATURE, AND DATE ON THE DRAWING. 4. PREVIOUS COMMENT; GENERAL: PROVIDE ENLARGED PLAN OF THE RESTROOMS. PROVIDE WALL ELEVATIONS INDICATING COMPLIANCE WITH THE ICC/ANSI A117.1-2003. 5. PREVIOUS COMMENT; SHEET a2.0; FLOOR PLAN KEY NOTES: NOTE 20 REFERENCES STRUCTURAL SHEETS NOT INCLUDED IN THIS SET. VERIFY. 6. PREVIOUS COMMENT; SHEET a2.0; GENERAL NOTES: NOTE 19 INDICATES THERE IS STRUCTURAL FRAMING ON A SHELL THAT NEEDS TO BE VERIFIED. CLARIFY. 7. PREVIOUS COMMENT; GENERAL: NEW MECHANICAL LOADS ON THE EXISTING ROOF NEED TO BE VERIFIED BY A STRUCTURAL ENGINEER THAT THE LOADS DO NOT EXCEED THE STRUCTURES CAPACITY. 8. PREVIOUS COMMENT; GENERAL: PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
06/01/2010 | ERIC NEWCOMB | ZONING HC | REVIEW | Denied | 1. PREVIOUS COMMENT: SEE BUILDING COMMENTS. |
06/07/2010 | RICK MYERS | PLUMBING-COMMERCIAL | REVIEW | Approved | 1. The applicable code for all commercial plumbing projects is the 2006 Uniform Plumbing Code with Local Amendments. |
06/08/2010 | RMYERS1 | WATER | REVIEW | Approved | |
06/08/2010 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Provide structural calculations and details to show that the Type I hood is supported from the building structure in accordance with Section 507.6, IMC 2006. Reference: Section 302.1, IMC 2006. 2. Provide sufficient information and details to show that the design and termination of the water heater vent complies with sections 510.6 and 511.0, UPC 2006. |
06/15/2010 | LEERAY HANLY | ELECTRICAL-COMMERCIAL | REVIEW | Denied | 1) NEC 210.8(B) GFCI PLUG RECEPTACLES REQUIRED IN COMMERCIAL KITCHENS. 2) NEC 110.3 PP-E3.O THE CALCULATED FAULT CURRENT AT PANEL B IS SHOWN TO BE 24,000 AMPS BUT KEYNOTE 2 TO SAME PANEL IS CALLING FOR 22K AIC BREAKERS. PLEASE CLARIFY. |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
06/15/2010 | ANY | REJECT SHELF | RECEIVED |