Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T10CM01234
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/05/2010 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. 2006 IBC REQUIRES SEPARATE RESTROOM FACILITIES FOR ASSEMBLY OCCUPANCIES PER SECTION 2902.2. VERIFY. 2. IF THE PATIO AREA SERVES DRINK AND/OR FOOD, THE SPACE MUST BE INCLUDED IN THE OCCUPANT LOAD CALCULATION. |
| 05/05/2010 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
| 05/05/2010 | ERIC NEWCOMB | ADA | REVIEW | Passed | |
| 05/05/2010 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 05/05/2010 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 05/05/2010 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Provide a direct waste connection for the wash and rinse sections of the 3-compartment sink, with an indirect connection for the sanitizing compartment only. Reference: Sections 304.0, 704.3, and 801.2.3, UPC 2006. 2. Provide an upper terminal cleanout for the dishwasher. Reference: section 707.4, UPC 2006. |
| 05/05/2010 | ERIC NEWCOMB | ZONING HC | REVIEW | Denied | 1. SEE BUILDING COMMENTS. |
| 05/06/2010 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 05/06/2010 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Passed | |
| 05/06/2010 | DAVE MANN | FIRE | REVIEW | Approved | |
| 05/07/2010 | GBONILL1 | WWM | REVIEW | Needs Review | |
| 05/07/2010 | GBONILL1 | ENGINEERING | REVIEW | Needs Review |