Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T10CM01189
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/01/2010 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Approved | |
| 07/01/2010 | TERRY STEVENS | ZONING | REVIEW | Approved | |
| 07/02/2010 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 07/02/2010 | LEERAY HANLY | HC | REVIEW | Approv-Cond | "Existing parking is non-conforming and may not be altered without full conformance to the LUC; full conformance is technically impossible given the site constraints. Additional accessibility is being provide to these historic buildings to the fullest extent technically feasible as addressed during meetings with the Building Official. Reference IBC 3406.1, 3407.1, 3409.1 exception, and 3409.4" ALSO SEE ATTACHED APPEAL FOR ACCESSIBILITY INTO UNITS |
| 07/02/2010 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 07/08/2010 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Select a consistent method for determining the fixture units and water demand; mixing UPC fixture units with IPC fixture units will not result in realistic demand values. The fixture units from the IPC are not the same as the fixture units in the UPC and the demand curves cannot be used interchangeably. Reference: Sections 604.1 and E101.1.1, IPC 2006. 2. Sizing of the branch piping shall be in accordance with Table 604.3, IPC 2006. The maximum flow rate for the PEX shall also be in accordance with the allowable friction loss calculated on sheet P2.1, and the PEX manufacturer's published friction data. Reference: Sections 604.1 and 604.3, IPC 2006. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/09/2010 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 07/09/2010 | SUE REEVES | REJECT SHELF | Completed |