Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - TI ALL
Permit Number - T10CM01169
Review Name: RESUBMITTAL - TI ALL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/01/2010 | DAVE MANN | FIRE | REVIEW | Approved | |
06/02/2010 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | 1. CONCERNING THE LETTERING SIZE (COMMENT 6) IT IS CLEAR THE UPPER CASE LETTERING MEETS THE MINIMUM 3/32" HEIGHT, BUT ALL LOWER CASE LETTERING IS LESS THAN THAT. THIS REVIEW HAS BEEN APPROVED. THIS NOTE IS FOR FUTURE REFERENCE ONLY. |
06/03/2010 | ERIC NEWCOMB | ZONING HC | REVIEW | Approved | |
06/04/2010 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Section R4-30-304 of the Rules of the Arizona State Board of Technical Registration, states that a notation shall be placed beneath the seal, either written, typed, or electronically generated, that provides the day, month, and year of the expiration of current registration. (Effective March 8, 2008). 2. Comment not resolved; indicate on the drawings which appliance needs which type of backflow protection device. Appliances (e.g. espresso makers, ice makers, etc) to be directly connected to the water supply system that do not have listed, integral backflow preventers or integral air gaps conforming to Table 6-3, UPC 2006 require backflow prevention. Specify the type of backflow prevention device required for each water connection. Reference: Sections 602.3, 603.0, and Table 6-2, UPC 2006. |
06/04/2010 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Section R4-30-304 of the Rules of the Arizona State Board of Technical Registration, states that a notation shall be placed beneath the seal, either written, typed, or electronically generated, that provides the day, month, and year of the expiration of current registration. (Effective March 8, 2008). 2. The minimum required ventilation is to be based on Table 403.3, IMC 2006 or an approved engineering analysis of the specific occupancy type. Reference: Sections 105.2 and 403.3, IMC 2006. |
06/10/2010 | LEERAY HANLY | ELECTRICAL-COMMERCIAL | REVIEW | Approved |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
06/23/2010 | CPIERCE1 | OUT TO CUSTOMER | Completed |
06/23/2010 | SUE REEVES | REJECT SHELF | Completed |