Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T10CM01094
Parcel: 136090380

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T10CM01094
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/17/2010 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Denied PLAN REVIEW COMMENTS T10CM01094

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the notated items indicating action taken.

SCOPE OF REVIEW:
The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2006 International Energy Conservation Code, and Arizona State amendments to the 2006 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:
Show corrections and revisions on original tracings or a finished reproducible set. Return two sets along with a set of the first submission for reference. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and notate sheets. (Do not cloud the changes made for comment revisions). Incorporate changes on originals and provide two copied sets for review.

All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration.

SITE PLAN:

1. Indicate the location of buildings, utility meters and electric lines from property line to building, R106.1.1.

FOUNDATION PLANS:

1. Indicate the slope for the garage slab, R309.3.
2. Show compliance with termite treatment, R320 as amended.

FLOOR PLANS:

1. Identify the dwelling room with a door entering the garage, R309.1.f.
2. Show the door from a garage to dwelling with a 20-minute fire rating (or 1-3/8" solid core) with self-closing and self-latching provision, 2006 IRC Amendment section 309.1.
3. Show a ½" gypsum board (garage side) on all walls common to the garage and house or other fire rated product in compliance with R309.2.

ELECTRICAL PLANS:

1. Designate the circuit number at the location of each light fixture, receptacle, appliance and equipment disconnect switch, E3603.5.
2. Show at least one GFCI receptacle outlet in the attached garage, E3801.9 & E3802.2.
3. Show at least one wall switch controlled light in attached garages, E3803.3.

If you have any questions please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review
06/22/2010 RONALD BROWN BUILDING-COMMERCIAL REVIEW Approv-Cond Please provide completed Special Inspection Certification for the inspections as outlined on sheet S1.1 for review and approval.

Final Status

Task End Date Reviewer's Name Type of Review Description
07/09/2010 SUE REEVES REJECT SHELF Completed
06/23/2010 GERARDO BONILLA OUT TO CUSTOMER Completed