Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T10CM01075
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/19/2010 | DAVID RIVERA | ZONING | REVIEW | Approved | |
| 07/19/2010 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 07/19/2010 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Approved | |
| 08/04/2010 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Date: 8-05-10 Activity: T10CM01075 Address: 2539 E. Linden St Applicant: Phat Tran Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: 1. Provide two copies of the corrected set of drawings and one set of the first submission for reference. All corrections and revisions shall be made on original tracings or finished reproducible set. Pencil and/or white out on final prints will not be acceptable. To expedite review, please cloud the originally submitted set with red ink and limit clouding on final set. Ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. FLOOR PLAN: 2. Specify nonabsorbent wall surface minimum 6' above the floor with fiber-cement board backing in tub/shower enclosures, R307.2, R702.4.2. STRUCTURAL / FRAMING PLAN: 3. Minimum of two (2) braced wall panels required along north side of addition, R602.10. 4. Specify beam size supporting carport rafters according to the proposed load, R802.1. 5. Clarify roof support at overhang on west side of addition. 6. Justify beam size over sliding glass door. SECTIONS - DETAILS: 7. Provide a detail that accurately reflects building condition (detail 1-4.0). PLUMBING PLAN: 8. Specify the diameter of the gas supply line. 9. Specify the diameter of the water supply line from the meter to the building entrance. 10. Verify lowest available water pressure (general note #20 states maximum 60 psi, plumbing schedule states 60+ psi -clarify) 11. Specify water conservation requirements: Water closets = 1.6 gallons per flush, Sinks = 2.2 gpm, Showerheads = 2.5 gpm, P2903.2. INTERNATIONAL ENERGY CONSERVATION CODE: 12. Specify the "R" value of the insulation, as well as the "U" factor and the solar heat gain coefficient of the windows and doors. Tucson is in climate zone 2B. The simplified prescribed energy values for glazing and skylights is U=0.75, ceiling R=30 and walls R=13. Mass wall requirement is R=4 when 50% of insulation is exterior and R=6 when applied interior, N1102.1. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/11/2010 | CPIERCE1 | OUT TO CUSTOMER | Completed |
| 08/11/2010 | SUE REEVES | REJECT SHELF | Completed |