Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T10CM01075
Parcel: 123022020

Address:
2539 E LINDEN ST

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T10CM01075
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/30/2010 GERRY KOZIOL WWM REVIEW Approved
05/24/2010 TERRY STEVENS BUILDING-RESIDENTIAL REVIEW Denied PLAN REVIEW COMMENTS T10CM01075

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the notated items indicating action taken.

SCOPE OF REVIEW:
The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2006 International Energy Conservation Code, and Arizona State amendments to the 2006 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:
Show corrections and revisions on original tracings or a finished reproducible set. Return two sets along with a set of the first submission for reference. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and notate sheets. (Do not cloud the changes made for comment revisions). Incorporate changes on originals and provide two copied sets for review.

Construction drawing guidelines are available from the residential desk of the Development Services Division. The plans must show compliance with current building codes before receiving permit approval.

FOUNDATION PLANS:
1. Locate and detail all footings (R301.1) for the following:
" Provide a dimensioned foundation plan for the addition.
" Posts or columns
2. Show the thickness and slope of all slabs (i.e. patio slabs and pads outside of doors), R301.1.
3. Provide a landing or floor surface at all exterior doors. A landing must be at least as wide as the door it serves and 36" in the direction of travel, R311.4.3.
4. Show or notate an 8" minimum separation of untreated exterior framing above finished grade, R319.1 item 2.
5. Show or notate a 6" minimum separation of untreated exterior posts or columns above finished grade and support by metal pedestal with 1" space above the floor, R319.1.4 exception 1.
6. Notate on the drawings the allowable soil bearing pressure used in the design of the footings. The maximum allowable foundation pressure is 1000 PSF with a 12" footing depth or per Table 1804.2 with an 18" footing depth, (IBC 1805.2 City of Tucson Amended).
7. Show the required minimum one #4 reinforcement rebar 3" from edge in the footer, R403.1. (City of Tucson Amended).
8. Dimension the footing length, width, and depth into undisturbed soil for each footing type and condition, R403.1.1.
9. Show the minimum 12" footing depth below undisturbed soil, R403.1.4.
10. Framed exterior walls of enclosed roof structures require continuous concrete footings of minimum 12" width and 12" below undisturbed ground surface, R403.1.
11. Locate and specify all anchor-bolt spacing on the foundation plan. Minimum ½" diameter with (anchor bolt length for assuring) 7" embedment into concrete or masonry, R319.1 & R403.1.6. Maximum spacing 6' o/c and within 12" of each sill plate end, R403.1.6.
12. Show the 6" (4" masonry veneer) minimum foundation height above finished grade, R404.1.6.

FLOOR PLANS:
1. Show a floor plan labeling all proposed and adjacent rooms and spaces, R106.1.1.
2. Show that each water closet is located in a clear space not less than 30" wide (centered 15" from finished wall or fixture) and has a clear space in front not less than 24", R307.1 & UPC 407.6.
3. Locate and identify brace wall type, R602.10.3 (include interior wall lines, R602.10.1.1) along with the appropriate tie-downs and nailing schedule, R602.10.8.
Locate and identify 4' brace wall panels at the ends (within 12.5') of all wall lines for avoiding the requirement of tie-downs at panels less than 4' wide, Table R602.10.6.

STRUCTURAL PLANS:
1. Provide complete roof framing plans. Show size, spacing and span of all framing members, trusses, joists, rafters, beams, glue-lams, lintels, headers, ledgers and blocking, R301.1.
2. Show size, spacing and span of all framing members, rafters, top sills and wall extensions (w/ tie straps), R301.1.
3. Completely detail all post connections from post base to the foundation, R301.1.
4. Show a beam size with appropriate load carrying capacity, R301.1.
5. Provide a header schedule and show existing opening sizes supporting new roof consistent with Table 502.5(1) & (2).
6. Specify steel lintels to support imposed load of the masonry veneer, R606.10:
1' to 4' 1-3 ½"x3 ½" x ¼"
7. Provide rafter sizes and spacing in compliance with Table R802.5.1.
8. Notate or detail double trimmer and headers with framing anchors (show sizes) at framed door and window openings exceeding 4', R802.9.

9. Specify eave/overhang length and detail outrigger support. - for 3' overhang on rear of addition
10. The detail indicating lag bolts into the end grain of the existing rafters is not allowed. A suggestion would be to set the new rafter on top of the existing top plate with a h2.5 connector.

ELEVATIONS:
1. Notate all roof slopes appropriate with selected material, R901.1. (Minimum allowable slope for Built-up roof is ¼" per foot, R905.9.1. Minimum allowable slope for Roll roofing is 1" per foot, R905.5.2.)

SECTIONS - DETAILS:
1. Show the ceiling gypsum board as either 5/8" or ½" sag resistant when applied to 24" o/c ceiling framing, IRC table R702.3.5 footnote d.
2. Specify veneer anchoring method, weepholes, water-resistive barrier and support (ties spaced max 24" o/c horizontally & vertically and supporting max of 2.67 SQ FT), R703.2 & R703.7.
3. Show 1" air space between sheathing and veneer R703.7.4.2.
Show method of flashing beneath the first course of veneer, R703.7.5.

PLUMBING PLANS:
1. Show which code is used for the plumbing design, 2006 UPC or 2006 IRC.
2. Provide a plumbing design using a single code, 2006 UPC or 2006 IRC.
3. Notate and specify all piping materials, UPC 301.1.1. IRC P2608.
4. Show the water heater with a pan having a drain to the building exterior, P2801.5.
5. Show a pressure and temperature relief valve at the water heater. A metallic T&P line must terminate at the exterior between 6 and 24 inches above grade and must terminate facing down, UPC 608.5. IRC P2803.6.1.
6. Clearly indicate if water heater is electric or gas.

WASTE AND VENTING:
1. Show the VTR size for the water closet (Min. 2") UPC 904.0, Table 7-5.
2. Provide vent piping through the roof with an aggregate cross-sectional area not less than that of the largest required building sewer, or not less than half of the connected drain area, UPC 904.1.

GAS:
1. Provide gas pipe sizes in compliance with connected demand, UPC 1217.2, & Table 12-8. IRC G2413.3 & Table G2413.4(1).
2. Provide the BTU demand of each appliance, total demand, and total developed length from meter to the most remote appliance on the system, and verify the size of the supply pipe for the connected demand (may require upgrading), UPC 1217.2, & Table 12-8. IRC G2413.3 & Table G2413.4(1).
3. Show a gas appliance vent connector with maximum length of 1.5' for each inch of connector diameter, G2428.3.2.

MECHANICAL PLANS:
1. Notate on plans: Mechanical comply with 2006 IRC chapters 12 - 24.
2. Provide heating facilities in all habitable rooms, R303.8.
3. Show flues connected to more than one appliance not less than the area of the largest connector plus 50% of the additional connectors. Water heater typical - 3" flue. See IRC section M1805.3.
4. Show combustion air compliance for appliances in confined spaces with two interior free area openings of 1 SQ IN for each 1,000 BTU rating and minimum of two 100 SQ IN openings, one within 12" of top and other 12" of bottom, G2407.5.3.1.
5. Show a minimum 2' termination above any roof point within 10' measured horizontally for gas flues G2427.5.3.

ELECTRICAL PLANS:
1. Notate on plan that all electrical work comply with 2006 IRC chapters 33 - 42.
2. Show locations of smoke alarm, R313. Notate that all smoke alarms must be interconnected with a power source from the building wiring, and be equipped with battery backup. When ceiling finish materials are removed in existing construction, existing bedrooms be in compliance. When ceiling finish materials are not removed, existing bedrooms may be equipped with battery operated smoke alarms, R313.2.
3. Smoke alarms are required outside each separate sleeping area, R313.2.
4. Interior alterations require the installation of smoke alarms at existing bedrooms, R313.2.1. Provide notation if existing or proposed.
5. Provide a panel schedule showing panel size, circuit numbers, ampacity, wire size and general description, E3304.11 & E3606.2. Provide a panel schedule showing wire size of each circuit or notate the wire size for each protection rating, E3602.2
6. Use Table E3602.13 for sizing 15, 20 & 30 AMP branch circuit conductors and protection ratings.
7. Designate the circuit number at the location of each light fixture, receptacle, appliance and equipment disconnect switch, E3603.5.
8. Show one 20 AMP branch circuit in the laundry area; this circuit may not serve other locations, E3603.3 and 3801.8.
9. Protect bedroom outlets including receptacles, lights and smoke detectors with combination type arc-fault circuit interrupters, E3802.12.
10. Show at least one wall-switch-controlled lighting outlet providing illumination on the exterior side of each outdoor egress door having grade level access R3803.3.
11. Notate light fixture placement in clothes closets in compliance with E3903.11.
12. Indicate the location of all disconnect switches for air handling equipment, E4001.5.
13. Show or notate a disconnect means or a locking breaker for the water heater, E4001.5.
14. Specify recessed lighting with 3" separation from combustibles or IC listing, R808, and compliance with energy efficiency leakage, N1102.4.3.

OUTDOOR LIGHTING CODE
1. Show compliance with City of Tucson Outdoor Lighting Code
2. Provide spec sheets for all full cut-off fixtures showing the lamp type, placement and fixture wattage. All other fixtures are assumed to be unshielded (non-FCO style). Fixtures are only exempt from the total lumen budget if both of the full cut-off FCO style and located under overhangs, OLC 5.1.2.


INTERNATIONAL ENERGY CONSERVATION CODE:

1. Tucson is in climate zone 2B. The simplified prescribed energy values for glazing and skylights is U=0.75, ceiling R=30 and walls R=13. Show the "R" values of insulation and the maximum "U" factors of the windows and doors on the plans as well as the solar heat gain coefficient SHGC minimum value of 0.40, N1101.2.
2. Clarify the insulation value at ceiling cavity locations less than 9-1/2" for compliance with N1102.4.
3. Both standard and high density R-30 batt insulation requires a space greater than provided with 2" x 8" framing. Identify the product that provides the intended value, or provide a ceiling cavity space for R-30 batt insulation.

If you have any questions please contact:
Terry Stevens
(520) 837-4961
City of Tucson Residential Plan Review

Final Status

Task End Date Reviewer's Name Type of Review Description
05/25/2010 GERARDO BONILLA OUT TO CUSTOMER Completed
05/25/2010 SUE REEVES REJECT SHELF Completed