Permit Review Detail
Review Status: Active
Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Permit Number - T10CM00936
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Active
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/08/2010 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | P&DS TRANSMITTAL FROM: Michael St.Paul, Planning Technician PROJECT: T10CM00936 532 West Simmons Road Addition to SFR TRANSMITTAL: April 8, 2010 COMMENTS: the following comments are relative to an application for a Design Development Option (DDO). This site is located in the R-3 Zone (LUC Section 3.2.6.2.A.1). The Development Designator is "I" (LUC Section 3.2.3.2.B) and the Perimeter Yard Indicator is AA (LUC Section 3.2.6.4). The minimum setback to an interior lot line equals the height of the structure's wall facing each property line (LUC Section 3.2.6.4). The height of the structure facing west is nine (9) feet, eight (8) inches and north ten (10) feet, four (4) inches. The required setback is nine (9) feet, eight (8) inches to the west property line and ten (10) feet, four (4) inches to the north property line (LUC Section 3.2.6.4). The required setback for the storage building along the east property line is eight (8) feet (LUC Section 3.2.6.4). The proposed setback is four (4) feet. |
| 04/08/2010 | ANY | BUILDING-RESIDENTIAL | REVIEW | Active | |
| 04/08/2010 | MICHAEL ST. PAUL | NPPO | REVIEW | Passed | |
| 04/08/2010 | ANY | WWM | REVIEW | Active | |
| 04/08/2010 | ANY | ENGINEERING | REVIEW | Active |