Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T10CM00778
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/26/2010 | DAVID RIVERA | ZONING | REVIEW | Approved | |
| 03/26/2010 | PAUL MACHADO | ENGINEERING | REVIEW | Approved | |
| 03/26/2010 | ERIC NEWCOMB | ADA | REVIEW | Passed | |
| 03/26/2010 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. PROVIDE STRUCTURAL CALCULATIONS FOR THE STOREFRONT FRAMING. |
| 03/26/2010 | ERIC NEWCOMB | ZONING HC | REVIEW | Approved | |
| 03/26/2010 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 03/29/2010 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Revise the font size used on the drawings to a minimum of 3/32-inch (all upper case). Reference: Section 106.1.1, IBC 2006. 2. Specify the minimum resistance (R-value) of the duct insulation to be used on this project. Reference: Section 503.2.7, IECC 2006, as amended by the City of Tucson. 3. Keynote 2, sheet M1.0 calls for 1200 CFM of outside air for the existing rooftop A/C unit but the outside air calculations on sheet M2.0 call for 1450 CFM of outside air. Coordinate the ventilation requirements. 4. Materials exposed in plenums shall conform to Section 602.2.1, IMC 2006. 5. Indicate the location of the smoke detectors for RTU-1. Reference: Section 606.1, IMC 2006. |
| 03/29/2010 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Provide cleanouts sized per Section 707.11, UPC 2006. 2. The specified model of tankless water heater is not capable of limiting the water temperature to 110 F. Specify a model that is capable of limiting the water temperature to 110F |
| 03/29/2010 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 03/29/2010 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 03/30/2010 | DAVE MANN | FIRE | REVIEW | Approved | |
| 04/01/2010 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Denied | Project: T10CM00778, 5870 E Broadway Bl TI for Guess The electrical plans have been denied for the following: 1. Actual Fault Current values to be listed for each panel. Sheet E0.0 Under Panelboards, #5 " actual AIC short current ratings to be verified on site." Please provide these, are required in order to approve plans for permit. 2. Some track lighting does not appear to be calculated at 150 va per every 2 feet.( NEC 2005, 220-43. B.) 3. Does load calculation for lighting include amount required for continous duty? Ray T Majuta, Elect Pln Ck PDSD, City of Tucson 4/05/10 Ray.Majuta@tucsonaz.gov |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/23/2010 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 04/23/2010 | SUE REEVES | REJECT SHELF | Completed |