Permit Number: T10CM00554
Parcel: 13631011Q

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T10CM00554
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/30/2010 GERRY KOZIOL WWM REVIEW Approved
05/11/2010 RONALD BROWN BUILDING-RESIDENTIAL REVIEW Denied GENERAL
1. The lettering size throughout all the sheets of the submitted documents do not comply with the minimum standard of 3/32". Please make all changes accordingly and resubmit.
RESUBMITTAL COMMENTS: NON-RESPONSIVE, LETTERING LESS THAN 3/32" IS UNACCEPTABLE. REWORK ALL LETTERING ON ALL SHEETS TO 3/32" OR HIGHER, UPPER AND LOWER CASE, AND RESUBMIT.

2. Please provide provide provide proper title for all plans and details with the appropriate scale indicated.
RESUBMITTAL COMMENTS
2A. TITLE BLOCK TITLE ARE SHEET TITLES. ALL THE FLOOR PLANS ARE DETAILS AND REQUIRE DETAIL TITLES INCLUDING A NORTH ARROW, DETAIL TITLE AND SCALE.
3. OK
SOLAR SYSTEMS
4. Starting July 1, 2009, all new single family homes or duplexes must include in the plans either a photovoltaic system or preparation for later installation of a PV system in order to receive a permit.
RESUBMITTAL COMMENTS
4A. Residential photo voltaic preparation must include ALL of the following:
1. Provide a Site Plan showing the best space available for accommodating Photo Voltaic (PV) equipment (meter, disconnect & inverter) with minimum area of 4 square feet. Locate the PV equipment adjacent to the electrical service panel if feasible or on a wall close to the proposed collector panel space.
2. Show on the Site Plan the best roof space available for accommodating PV solar collector panels. Provide a roof structure designed for the additional collector dead loading (typically 4 psf).
3. Show a minimum 3,800 volt-ampere PV electrical load entry on the Service Load Calculation. This load is continuous as with heating and cooling loads.
4. Show an Electrical Panel Schedule with a 240 volt circuit breaker space labeled "reserved for Photo Voltaic".

5. All SFR and Duplex plans submitted after March 1, 2009 require a solar water system, or future installation preparation with one of the following provisions: control and ¾"water piping; 3" metallic sleeve; or an accessible attic over the water heater.
RESUBMITTAL COMMENTS:
5A. SOLAR WATER HEATING PREPARATION MUST INCLUDE ONE OF THE FOLLOWING LISTED ABOVE SHOWN ON THE DRAWINGS IN IT'S APPROPRIATE PLACE.
SITE PLAN:
6. OK
7. OK
8. Provide gas piping for structure or submit exemption documentation, Arizona Statute 30-809.
RESUBMITTAL COMMENTS:
8A. PLEASE SUBMIT EXEMPTION DOCUMENTATION AS PER ARIZONA STATUTE 30-809

9. Provide compliance with the Inclusive Home Design Ordinance Number 10463 and show on drawings.
RESUBMITTAL COMMENTS
9A. THE ENCLUSIVE HOME DESIGN IS MORE THAN PROVIDING A DRIVE WAY AND WIDENING SOME DOORS.
1. THE DRIVE MUST BE ACCESSIBLE AS PER ANSI 117.1, SECTION 402.
2. FOR OTHER REQUIREMENTS, PLEASE READ THE INCLUSIVE HOME DESIGN ORDINANCE LOCATED ON THE P & DSD WEB SITE.
3. PLEASE BE AWARE OF SECTION 103.1: WAVIER PROVISIONS.

10. OK
SECTIONS - DETAILS:
11. OK
ELECTRICAL PLANS:
12. Show electrical service to structure and size of service conduit as required.
RESUBMITTAL COMMENTS
12A. TEP REQUIRES A 2½ DIAMETER SERVICE CONDUIT TEP SR-305.
12B. PLANS SHOW AN ARROW AND A NOTE. PLEASE DRAW IN THE PANEL BOX AND IT'S EXACT PHYSICAL LOCATION

13. OK
14. OK
15. Show the location of the panel with a 30”W x 36”D clear working space, E3305.2, E3501.6.2.
15B. SHOW THE PANEL BOX AND IT'S EXACT PHYSICAL LOCATION

PLUMBING PLANS:
17. Provide a full set of plumbing along with design perameters of septic system as required.
RESUBMITTAL COMMENTS:
17A. PROVIDE A FULL AND COMPLETE SET OF PLUMBING DRAWINGS ALONG WITH DESIGN PARAMETERS OF SEPTIC SYSTEM AS REQUIRED.


MECHANICAL PLANS:
18. OK
19. OK
20. OK
21. OK
OUTDOOR LIGHTING CODE
22. OK
23. OK
INTERNATIONAL ENERGY CONSERVATION CODE:
24. OK
END OF RESUBMITTAL REVIEW