Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T10CM00525
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/19/2010 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | Cost estimate update needed seperating out material and labor. Sign and date cost estimate. |
| 05/19/2010 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 05/21/2010 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 06/09/2010 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Comment not resolved; show the required listing requirements on the drawing (e.g. "All fixtures shall be NSF listed"). Provide material standards for all plumbing fixtures being provided by others. All plumbing fixtures and fittings shall be listed or labeled by a nationally-recognized, accredited conformity assessment company (e.g. UL, ETL, UPC, etc). Reference: Sections 301.1.1 and 401.1, UPC 2006. 2. The proposed grease interceptor and the sizing method shown on sheet P1.1 are not in accordance with the requirements of Section 1014.3, UPC 2006. Submittal of an Appeal to the Building Official to use an alternative method for grease interception will be required. Reference: Sections 301.2 and 1014.3, UPC 2006. 3. Comment not addressed. Clarify how the domestic dishwasher (K-5) will be drained. Reference: Sections 103.2.3 and 807.4, UPC 2006. 4. Clarify how FS-1 will be installed; is it to be installed with its flood rim flush with the floor to allow it to act as a floor drain as well as an indirect waste receptor? Reference: Sections 411.2704.3, and 804.0, UPC 2006. |
| 06/09/2010 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | Coordinate the structural calculations and details showing how the Type I hood is to be supported from the building structure with the wall construction shown in detail 7/A1.0. Reference: Sections 302.1, 507.6, and 507.9, IMC 2006. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/16/2010 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 06/16/2010 | SUE REEVES | REJECT SHELF | Completed |