Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T10CM00525
Parcel: 12605146H

Review Status: Completed

Review Details: COMMERCIAL TI

Permit Number - T10CM00525
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/04/2010 MICHAEL ST. PAUL ZONING REVIEW Approved
03/04/2010 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Approved
03/04/2010 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Denied 1. SHEET A1.0; KEYNOTE 9: THERE IS NO STRUCTURAL INCLUDED ON THIS PROJECT. REVISE NOTE.
2. GENERAL: PROVIDE THE LATERAL BRACING OF THE NEW INTERIOR WALLS TO MEET THE REQUIREMENTS OF THE IBC SECTION 1607.13. INCLUDE THE BRACING SIZE AND SPACING, CONNECTION OF THE BRACING TO THE FRAMING ABOVE, AND CONNECTION OF THE BRACING TO THE TOP OF THE WALL.
3. SHEET M1.1; DETAIL 6: PROVIDE AN ENLARGED DETAIL TO INDICATE THE CONNECTION OF THE HOOD SUPPORTS/HANGERS TO THE EXISTING STRUCTURE.
4. SHEET M1.1; DETAIL 4: PROVIDE AN ENLARGED DETAIL TO INDICATE THE CONNECTION OF THE EVAPORATIVE COOLER ANGLE STAND BEARING PLATES TO THE EXISTING STRUCTURE.
03/04/2010 ERIC NEWCOMB ZONING HC REVIEW Approved
03/04/2010 BETH GRANT COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
03/04/2010 ERIC NEWCOMB ADA REVIEW Passed
04/19/2010 DROBEY1 MECHANICAL-COMMERCIAL REVIEW Needs Review
04/19/2010 DROBEY1 FIRE REVIEW Needs Review
04/19/2010 DROBEY1 WATER REVIEW Needs Review
04/19/2010 DROBEY1 PLUMBING-COMMERCIAL REVIEW Needs Review
04/19/2010 DROBEY1 WWM REVIEW Needs Review
04/19/2010 LOREN MAKUS ENGINEERING REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
04/19/2010 DELMA ROBEY OUT TO CUSTOMER Completed