Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T10CM00441
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
02/23/2010 | STEVE SHIELDS | ZONING | REVIEW | Passed | |
02/23/2010 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Approv-Cond | |
02/23/2010 | ERIC NEWCOMB | ADA | REVIEW | Passed | |
02/23/2010 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Needs Review | |
02/23/2010 | ERIC NEWCOMB | ZONING HC | REVIEW | Needs Review | |
02/23/2010 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
02/24/2010 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | Provide calculations demonstrating adequate ventilation. Reference: Section 401.2, IMC 2006. |
02/24/2010 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
02/24/2010 | ROBERT SHERRY | WATER | REVIEW | Approved | |
02/24/2010 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Provide structural justification for the use of a horizontal vent (i.e. a "flat vent") that does not rise vertically to a minimum of 6" above the flood rim of a fixture before it offsets horizontally. Reference: Section 905.3, UPC 2006. 2. Show that the floor of the restroom slopes toward the floor drain. Reference: Section 411.2, UPC 2006. 3. Clarify the CW & HW riser diagram. What is HB2? Are there really two water heaters (WH1 and WH2)? The lavatories are equipped with a thermostatic mixing valve and are scheduled with both CW and HW. 4. The maximum water use for a urinal is 1.0 GPF, per ARS Title 45, Chapter 1, Article 12. (See text at: http://www.azleg.state.az.us/ArizonaRevisedStatutes.asp). |
02/25/2010 | GERRY KOZIOL | WWM | REVIEW | Denied | |
02/25/2010 | DAVE MANN | FIRE | REVIEW | Approved |