Permit Number: T10CM00422
Parcel: 117072430

Address:
742 S 3RD AV

Review Status: Completed

Review Details: RESIDENTIAL BLDG/ZONING-WALKTHRU

Permit Number - T10CM00422
Review Name: RESIDENTIAL BLDG/ZONING-WALKTHRU
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/22/2010 SSHIELD1 NPPO REVIEW Passed
02/22/2010 STEVE SHIELDS ZONING REVIEW Denied PDSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: 742 S. 3rd Avenue
T10CM00422
Room Addition to Existing dwelling, bath and porch to existing out building and new car cover.
Residential Building Plan (1st Review)

TRANSMITTAL DATE: February 22, 2010

1. Historic review required for Room Addition to existing residence, porch to existing out building and new car cover.

2. Per LUC Section 3.2.6.4, Development Designator "I" required perimeter yard setback for the proposed addition to the existing residence to the north property line is the height (H) 9'-3", proposed is 6'-0".

3. Per LUC Section 3.2.6.4, Development Designator "I" required perimeter yard setback for the proposed addition to the existing residence to the south property line is the height (H) 9'-3", proposed is 5'-3".

4. Per LUC Section 3.2.6.4, Development Designator "I" required perimeter yard setback for the proposed porch addition to the existing out building to the south property line is the height (H) 7'-0", proposed is 6'-6".

5. Per LUC Section 3.2.6.4, Development Designator "I" required perimeter yard setback for the proposed new car cover to the north property line is the height (H) 8'-0", proposed is 5'-0".

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956

C:\planning\grading\t10cm00422.doc
04/26/2010 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Needs Review
04/26/2010 LOREN MAKUS ENGINEERING REVIEW Approved