Permit Number: T10CM00298
Parcel: 13322471B

Review Status: Completed

Review Details: COMMERCIAL TI

Permit Number - T10CM00298
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/09/2010 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
02/09/2010 LEERAY HANLY MECHANICAL-COMMERCIAL REVIEW Denied EF-1 FANS ARE UNDERSIZED FOR EXHAUSTING SUPPLY AIR BEING PROVIDED TO RESTROOMS.

MECHANICAL PAGES INDICATE A TIME CLOCK SHALL BE INSTALLED SO THAT EF-1 FANS ARE ON WHILE BUILDING IS OCCUPIED, BUT ELECTRICAL PAGES SHOW THEM BEING SWITCHED.
02/09/2010 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Approved
02/09/2010 PAUL MACHADO ENGINEERING REVIEW Approved
02/09/2010 BETH GRANT COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
02/09/2010 RICK MYERS PLUMBING-COMMERCIAL REVIEW Denied 1. All fixure traps require vents. Reference: 901.0 2006 UPC. See sheet P-1 detail five; floor sink. 2. Include how the water is to be sterilized. Reference: 609.9 2006 UPC. 3. Show the size of the grease trap. A hydo mechanical grease interceotor will require a vented flow control device installed in a visible, and readily accessible location. 4. See sheet P-1, detail four- electric water heater. Include heat traps or heat trap fittings, when using 2006 IECC requirements for insulating first eight feet of hot and cold water piping from the water heater. 5. Include water calculations for determaining the sizes of water pipes to all fixtures. Show the pipe sizes to each fixture in the childs restroom.
02/09/2010 ERIC NEWCOMB ADA REVIEW Passed
02/09/2010 ERIC NEWCOMB ZONING HC REVIEW Approved
02/17/2010 CPIERCE1 WWM REVIEW Needs Review
02/17/2010 CPIERCE1 ZONING REVIEW Needs Review
02/17/2010 CPIERCE1 WATER REVIEW Needs Review
02/17/2010 CPIERCE1 FIRE REVIEW Needs Review