Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T10CM00216
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/02/2010 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS T10CM00216 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2005 National Electrical Code and Arizona Revised Statutes. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: All corrections and revisions shall be made on original tracings or a finished reproducible set. Return two sets along with a set of the first submission for reference. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. (Do not cloud the changes made for comment revisions). Incorporate changes on originals and provide two copied sets for review. All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. GENERAL NOTES: " Provide ¼" = 1' scaled drawings with legible notation (minimum 3/32" lettering). Enlarge block labels sheet SE1.2. " Provide manufacturer specification sheets for water collector panels, controller and storage devices. " Show the solar water electrical panel and water heater disconnect switch E4001.5. STRUCTURAL PLANS: 1. Provide complete roof framing information for determining load carrying capacity for the roof structure. Demonstrate the ability for supporting the existing and additional dead load along with a 20 PSF live load for field assembled structures, or show that each engineered truss receives no more than 200 pounds of additional dead loading, or provide an engineer's calculation, design and seal for verifying the truss load carrying capacity, M1401. 2. Provide complete roof framing information for determining load carrying capacity of the structure supporting the water collector group referenced on sheet SP1.2. CALCULATIONS 1. Maximum Photovoltaic System Voltage (Voc x 1.13) NEC 690.7 and Table 690.7 (16 degrees F). Show an inverter with appropriate specifications for this calculation. The selected inverter has a maximum input voltage of 550 VDC. 2. Show a DC grounding electrode conductor size equal to the neutral conductor and not smaller than #8 (copper), NEC 250.166. NOTES / SPECIFICATIONS 1. Provide the exact wording and location for the DC Power Source including the "Vmp" marking required by NEC 690.53. The calculation shows 534 VDC. 2. Provide the location for the "backfed" circuit breaker in compliance with NEC 690.64 (B) (5). 3. Specify that the module interconnection (MC) connectors shall be marked for positive and negative polarity. Reference NEC 690.33 (A). 4. Specify and show a continuous Grounding Electrode Conductor. (Reference NEC 250.64 (C), 250.160. If you have any questions please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/10/2010 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 02/10/2010 | SUE REEVES | REJECT SHELF | Completed |