Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T10CM00201
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/26/2010 | TERRY STEVENS | ZONING | REVIEW | Approved | |
01/26/2010 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
01/26/2010 | ERIC NEWCOMB | ADA | REVIEW | Passed | |
01/26/2010 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. SHEET IA1.0: NO EGRESS IS ALLOWED THROUGH STORAGE AREAS PER IBC SECTION 1014.2(2). 2. GENERAL: A MINIMUM LETTERING HEIGHT OF 3/32" IS REQUIRED ON ALL DRAWINGS (SHEETS IA1.1 & IA3.0). |
01/26/2010 | ERIC NEWCOMB | ZONING HC | REVIEW | Denied | 1. SEE BUILDING COMMENTS. |
01/26/2010 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Approved | |
01/27/2010 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Revise the ventilation calculations to take into account the different occupancy loads in the project space. Reference: Sections 403.3 and 403.3.2, IMC 2006. |
01/27/2010 | LEERAY HANLY | ELECTRICAL-COMMERCIAL | REVIEW | Needs Review | |
01/27/2010 | ROBERT SHERRY | WATER | REVIEW | Approved | |
01/27/2010 | MARTIN BROWN | FIRE | REVIEW | Approved | |
01/27/2010 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | The branch piping size called out for the urinal flush valve will result in a water velocity greater than 8 FPS. Limit the water velocity to less than 8 FPS for the copper piping. Reference: Section A 6.1, UPC 2006 and IS 3-2003, Section 2.6. |
02/01/2010 | GBONILL1 | WWM | REVIEW | Needs Review |