Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T10CM00200
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/26/2010 | BRAMIRE1 | LANDFILL | REVIEW | Passed | |
| 02/01/2010 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 02/23/2010 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Date: 2-26-10 Activity: T10CM00200 Address: 3447 N. Olsen Applicant: Eric Hager Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: 1. Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. 2. Provide gas piping for structure or submit exemption documentation, Arizona Statute 30-809. INCLUSIVE HOME DESIGN: 3. Provide all switches, receptacles, and controls within 48 inches of the floor but not less than 15 inches above the floor (To include thermostat controls), 1003.9. STRUCTURAL / FRAMING PLAN: 4. Provide interior braced wall line from east to west for exterior walls lines that exceed 35' on center, R403.1.6, R602.10.1.1, R602.10.8. 5. Detail provided for non-vented roof assembly is not an approved detail; provide roofing material manufacturer that will guarantee their product without attic ventilation. PLUMBING PLAN: 6. Provide note requiring that water hammer arrestors be installed in accordance with ASSE 1010-2004 on water lines serving appliances equipped with quick-closing valves to include but not limited to: clothes washers, dishwashers, and refrigerators, UPC 609.10. MECHANICAL PLAN: 7. Show supply and return air ducts with a minimum R-8 insulation when located outside the thermal envelope, R1103.2.1. INTERNATIONAL ENERGY CONSERVATION CODE: 8. The simplified prescribed energy values for walls is R=13, N1102.1. Correct general note for 2x4 exterior walls. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/04/2010 | BETH GRANT | OUT TO CUSTOMER | Completed |
| 03/04/2010 | SUE REEVES | REJECT SHELF | Completed |