Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T10CM00119
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/11/2010 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 06/28/2010 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS T10CM00119 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the notated items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2006 International Energy Conservation Code, and Arizona State amendments to the 2006 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: Show corrections and revisions on original tracings or a finished reproducible set. Return two sets along with a set of the first submission for reference. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and notate sheets. (Do not cloud the changes made for comment revisions). Incorporate changes on originals and provide two copied sets for review. All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. The City of Tucson adopted the 2006 IRC with amendments on 6/12/2007 and the 2006 UPC with amendments on 7/10/2007. For initial construction: Effective 1/1/2007 the Inclusive Home Design; starting 3/1/2009 Solar Water Preparation and 7/1/2009 Solar Photo-Voltaic Preparation are required for all new SFR and duplex plans. Show the code references on the plans. Amendments to adopted codes are at the City web-site http://www.tucsonaz.gov: Planning, Building, & Business; under the Building topic; Building Ordinances and Codes; Building Codes GENERAL NOTES: " All SFR and Duplex plans submitted after March 1, 2009 require a solar water system, or future installation preparation City of Tucson Ordinance #10549 with one of the following provisions: ½"control conduit and two ¾" copper piping for water with rooftop termination; straight 3" metallic sleeve; or an accessible attic (clear path 30" wide x 30" high) over the water heater. Show appropriate notation. " All SFR and Duplex plans submitted after July 1, 2009 require a solar photo-voltaic system, or future installation preparation City of Tucson Ordinance #10549 with the following provisions: 1. A 4 square feet area for (meter, disconnect & inverter) equipment adjacent to the electrical service panel or near the proposed collector panel space. 2. The best roof space available for accommodating PV solar collector panels with capacity for collector dead loading (typically 4 lbs/SF). 3. A minimum 3,800 volt-ampere PV electrical load entry on the Service Load Calculation (Show as a continuous load of 15.8 A). 4. An Electrical Panel Schedule with a 240 volt circuit breaker space labeled "reserved for Photo Voltaic". Show appropriate notation. STRUCTURAL PLANS: 1. Notate on the drawing that pre-stressed or post-tensioned walls are permanently labeled at the center of the garage door opening as well as with a metal tag indicating 'POST TENSIONED WALLS' permanently attached to the main water shut off valve. A special inspection request is required with the permit application. 2. Show a joist size with appropriate load carrying capacity, R301.1. The 11-7/8" engineered joist may not span over 20' with a 110 series joist. Clarify Roof Framing keynote 'A' on sheet A-4. 3. Show a beam size with appropriate load carrying capacity, R301.1. Size B-4 shown on sheet A-4. 4. Notate a proposed location and weight of the HVAC and future Solar Panel loads on the roof framing plan for verifying the truss load carrying capacity used for the engineered joist design, R301.1 & M1401. 5. Provide an engineer's calculation, design and seal for masonry partition and screen walls exceeding 6' in height above grade on either side. Place seal on Detail B of DDO approval plan set. SECTIONS - DETAILS: 1. Show the ceiling gypsum board as either 5/8" or ½" sag resistant when applied to 24" o/c ceiling framing, IRC table R702.3.5 footnote d. Notate sheet A-6. PLUMBING PLANS: 1. Provide water hammer arresters wherever quick-closing valves are installed in a water distribution system. The devices should conform to ASSE 1010-2004. Water hammer arresters are required for clothes washer, dishwasher and refrigerator water connections, UPC 609.10. 2. Provide a revised fixture unit schedule showing 4 fixture units for a tub and include the garage sink, UPC 610.8, Table 6-6. Revise the fixture total. 3. Show a clean out at the kitchen sink area UPC 707.4 W/ State amendment. 4. Revise the CFH total using a ratio of 1 CFH for each 1,000 BTU demand. UPC 1217.2, & Table 12-8 requires a 1-1/4" gas service pipe when the total developed length is listed over 70' at 225 CFH. 5. Show a provision for a future solar water system, City of Tucson Ordinance #10549. ELECTRICAL PLANS: 1. Notate on plan that all electrical work complies with 2006 IRC rather than UPC. Revise references within notes #3, 4D, 5, 7, 8, 11 & 12. 2. Add a double breaker space for future Photo Voltaic on the panel schedule, E3304.11 & E3606.2. 3. Show the location of a typical electrical panel on the Electrical Plan with 4 square feet of clear area for future Photo Voltaic equipment, E3501.6.2 & E3605.8. 4. Revise the electrical load calculation showing a minimum 3,800 volt-ampere or 16 Ampere 100% entry for future Photo Voltaic equipment, E3502.2. 5. Specify interior recessed lighting with 3" separation from combustibles or IC listing, R808, and compliance with energy efficiency leakage, N1102.4.3. OUTDOOR LIGHTING CODE 1. Provide spec sheets for all full cut-off fixtures showing the lamp type, placement and fixture wattage. All other fixtures are assumed to be unshielded (non-FCO style). Fixtures are only exempt from the total lumen budget if both of the full cut-off FCO style and located under overhangs, OLC 5.1.2. If you have any questions please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/15/2010 | SUE REEVES | OUT TO CUSTOMER | Completed |
| 07/15/2010 | SUE REEVES | REJECT SHELF | Completed |