Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING-WALKTHRU
Permit Number - T10CM00119
Review Name: RESIDENTIAL BLDG/ZONING-WALKTHRU
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/20/2010 | DAVID RIVERA | ZONING | REVIEW | Denied | DDO Comments TO: Zoning Administration Michael Taku FROM: David Rivera Principal Planner PROJECT: 2610 E. Croyden St New SFR and & 7-foot high patio wall. (R-1 Zoning) TRANSMITTAL: January 20, 2010 (DDO comments review) Applicant proposes to demo existing SFR and construct a new 3175 square foot SFR. Applicant proposes to construct a seven (7) foot high masonry wall along the west, south, and east property lines. DDO required for east building setback. Owner proposes a three (3) foot setback. The required setback based on the proposed building height of 13'-4" from design grade is 8.9'. (LUC section 3.2.6.4 perimeter yard indicator AA, requires that a minimum of six (6) feet or two-thirds the height of the structure the greatest of the two.) DDO required for proposed seven (7) foot high perimeter screen wall. Request to construct the wall on the west, south, east property lines. 3.2.5.2 H. The maximum height of a wall or fence within a perimeter yard is six (6) feet; however, the wall or fence may be higher than six (6) feet, but no higher than ten (10) feet, if: (See Illustration 3.2.5.2.H. Owner wishes to construct the to seven feet in height without any openings as allowed per LUC section 3.5.2.4.H |
| 04/06/2010 | CPIERCE1 | ENGINEERING | REVIEW | Needs Review | |
| 04/06/2010 | CPIERCE1 | NPPO | REVIEW | Needs Review | |
| 04/06/2010 | CPIERCE1 | BUILDING-RESIDENTIAL | REVIEW | Needs Review |