Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T10CM00063
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/12/2010 | DAVE MANN | FIRE | REVIEW | Approved | |
01/14/2010 | PAUL MACHADO | ENGINEERING | REVIEW | Approved | |
01/14/2010 | MICHAEL ST. PAUL | ZONING | REVIEW | Approved | |
01/20/2010 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | Project: T10CM00063 5515 E 5th St, OFFICE The electrical plans for this project denied for the following, 1. The feeders from the CT can show 8 #3/0's and 2 # 6 grd's. The grounds must be sized per 2005 NEC 250-66 since the is no overcurrent device ahead of this feeder. Now they appear to be sized per 250-122. 2. Circuits A-2 and 4 are reversed per panel and power plan. 3. Provide a time clock for exhaust fan in restroom as required for exhaust to come on during work hrs, or other means. Ray T Majuta Elect Pln CK PSDS, c of t. 1/20/10 520/837/4988 |
01/20/2010 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Approved | |
01/20/2010 | RONALD BROWN | ZONING HC | REVIEW | Approved | |
01/20/2010 | RONALD BROWN | ADA | REVIEW | Passed | Not a COT owned/operated property |
01/21/2010 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
01/21/2010 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
01/21/2010 | ROBERT SHERRY | WATER | REVIEW | Approved | |
01/21/2010 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Approved | |
01/21/2010 | GERRY KOZIOL | WWM | REVIEW | Approved |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
01/28/2010 | DELMA ROBEY | OUT TO CUSTOMER | Completed |