Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T10CM00041
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/20/2010 | GERRY KOZIOL | WWM | REVIEW | Denied | NEED 5TH FLOOR WASTEWATER CREDIT EVALUATION FOR DEMO OF 2 TOILETS AND 2 LAVS PER DEMO DRAWINGS 740-6602 OR 740-6606 |
01/21/2010 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Denied | SHEET A000 1. Please revise your PROJECT CODE ANALYSIS schedule to read ACCESSIBILITY: 2006 IBC, Chapter 11 and ICC (ANSI) 117.1, 2003 Edition and the ENERGY CODE to read 2006 International Energy Code plus local Amendments. SHEET S-1 2. Please provide Special Inspections as per structural notes on sheet S1. ARCHITECTURAL, MECHANICAL AND ELECTRICAL SHEETS IN GENERAL 3. Minimum lettering fonts 3/32" high for upper and lower case. Architectural specs on sheet A600 and mechanical and electrical specifications are not in compliant. Please revise and resubmit. 4. Please provide a bracket suspension detail for the water heater support. SHEET A501: 5. Most all accessible toilet elevations on this sheet were designed with ADAAG standards. a. As per Comment 1 above, the required accessible guidelines are as per 2006 IBC, Chapter 11 and ICC (ANSI) 117.1. Please redesign all accessible details accordingly and correct all dimensions. b. Please include a vertical grab bar as required by ICC (ANSI) 117.1 Section 604.5.1. 6. At detail 5, please substitute ICC (ASNSI) 117.1 guidelines in lieu of the ADAAG reference. END OF REVIEW |
01/21/2010 | RONALD BROWN | ZONING HC | REVIEW | Denied | reference building - commerical folder for comments |
02/01/2010 | RICK MYERS | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Item not addressed. The applicable code for all commercial plumbing projects is the 2006 UPC with local ammendments. Provide an approved appeal to the building official if the plans are to be reviewed to the 2006 IPC. |
02/01/2010 | RICHARD JIROUDEK | ELECTRICAL-COMMERCIAL | REVIEW | Denied | Electric Plans Denied For The Following: 1. Provide GFI receptacles for servicing RTU's. 2005 NEC 210.63 2. Provide switch for control of lighting in electric room. Not to be controlled by automatic means. 2005 NEC 110.26(D) 3. Revise sequence of operation for restroom exhaust fans so fans operate whenever HVAC equipment is supplying air to restrooms. See Mechanical Review comments. 2006 IMC 403.2.1 Rich Jiroudel Electric Plns Exmn 520-954-0161 |
02/02/2010 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | Item not addressed. Revise the sequence of operation for the restroom exhaust fans so that recirculation of the air from the restroom will not occur (i.e. the restroom fans shall operate whenever the HVAC system is supplying air to the restrooms). Reference: Section 403.2.1, IMC 2006. |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
02/04/2010 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
02/04/2010 | SUE REEVES | REJECT SHELF | Completed |