Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Permit Number - T10CM00023
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/07/2010 | ANDREW CONNOR | NPPO | REVIEW | Denied | According to the approved tentative plat this site is subject to the provisions provided in: CITY OF TUCSON DEVELOPMENT STANDARD NO. 9-01.0 HILLSIDE DEVELOPMENT ZONE Add the following notes to site/grading plan pertaining to: Vegetation Retention and Re-vegetation: 1. Existing trees with four (4) inch or greater trunk diameter and cacti will be preserved in their original locations, except for building sites and access and utilities serving building sites. 2. When retention of the above trees and cacti in their original locations is not possible due to building site location, the trees and cacti will be salvaged and replanted in areas requiring re-vegetation, whenever possible. B. Re-vegetation. All cut or fill slopes, which are no steeper than three (3:1) and all utility trenches or septic leaching fields which are not located in parking or driveway areas will be re-vegetated in compliance with the following requirements. 1. All plants used in revegetation must be the same as the native vegetation on the site or any adjacent site prior to grading or clearing. 2. Revegetation will be accomplished with the following minimum requirements for plants. a. Desert trees, a minimum of fifteen (15) gallon size with a minimum trunk diameter of two (2) inches measured at the soil level, or large specimen cactus will be placed at the same vegetation density found on the site prior to any clearing, grubbing, or grading. b. Seeds for trees, desert shrubs, and grasses will be planted with a density adequate to control erosion and may use one of the following methods of planting or any other method approved by the Zoning Review Section at DSD. 1) Raked into the soil with appropriate mulch materials; 2) Hydro-seeding; 3) Anchored mulches; or 4) Established on jute, rolled straw, or similar material. NPPO PRE PERMIT INSPECTION MUST BE PERFORMED PRIOR TO GRUBBING OR GRADING. Fencing shall be required during construction per DS 2-06.8.0 Fig.1 for all undisturbed natural desert areas of Protected Native Plants and for individual Protected Native Plants to be preserved-in-place. The area to be fenced shall be beyond the "drip-line" of the vegetation by one-half (½) the distance of the "drip-line" radius. For Saguaros and cacti, the area to be fenced shall be equal to the distance of one-half (½) the height of the plant per DS 2-15.6.0 |
| 01/07/2010 | MARTIN BROWN | FIRE | REVIEW | Denied | Automatic fire sprinklers required due to fire access. |
| 01/08/2010 | DAVID RIVERA | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: David Rivera Principal Planner PROJECT: T10CM00023 10765 E Placita Merengue Proposed Single Family Residence TRANSMITTAL DATE: January 8, 2010 COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Address the following items on the site plan. a. Add the building setbacks from all property lines to the structures. b. Revise the lot coverage calculations to identify all areas that are to be included in lot coverage, driveway, all enclosed structures which include the dwelling, carports, garages, and accessory structures. Open porch structures or pools are not included in the coverage. List these areas as Dwelling, carport/garage, driveway, accessory structure(s) etc. See the attached plot plan requirements. 2. See the attached copies of the tentative plat and final plat documents and address the following items. a. Per document one (1) tentative plat, the maximum allowable buildable area is 43% of 1.48 Acres. Clearly define the buildable area and list the square footage/acreage not to exceed 43%. Access areas do not count towards the buildable area. b. Per Document one (1) tentative plat, slopes equal to or exceeding 25% shall not be used for development except as required for access and utility construction. Clearly delineate and label these areas. c. Once the grading plan is approved the plot plan can be approved by zoning. The building plans will be reviewed after the residential reviewers have had a chance to review the plans. Building cannot be approved until the grading plan and plot plan is approved. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. C:\DSD\T10CM00023.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised grading and site plan and additional requested documents |
| 01/13/2010 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 01/26/2010 | ELIZABETH LEIBOLD | ENGINEERING | REVIEW | Approved | DATE: January 26, 2010 TO: Simons Home Design SUBJECT: Rancho Cancion lot 3 Engineering SFR Review Submittal ADDRESS: 10765 E PLACITA MERENGUE REVIEWER: Elizabeth Leibold ACTIVITY NUMBER: T10CM00023 SUMMARY: The SFR site plan submittal was received and reviewed. Engineering recommends approval of the site plan with the following discussion regarding the grading plan. A grading permit will be required for this project. Address all redline comments from the counter review. You may submit the site plan as a Site/Grading Plan and provide all the information on the Site/Grading Plan sheets, or have separate grading plan sheets. On the grading plan show all lot linework as depicted on the Final Plat, and any easements are delineated and labeled. Per Development Standards (DS) Section 9-04.3, LUC 2.8.1, and as discussed at the counter, the grading plan shall show any revised FFE, design shall reflect any geotechnical recommendations, and slopes shall blend with the natural appearance of the site or lot and the surrounding terrain, with the use of handplaced rip rap and terracing. Show on planview and provide cross sections that clarify and shows the revised rear slope configuration. If FFE changes, a revised Site Plan is needed. Slopes equal to or exceeding 25% shall not be used for development except as required for access and utility construction. Clearly delineate and label these areas. If you have questions or would like to set up a meeting, call me at 837-4934. Elizabeth Leibold, PE Civil Engineer Engineering Division Development Services Department |
| 02/01/2010 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. STRUCTURAL CALCULATIONS; SHEET 1: REFERENCE TO THE IBC TABLE 1609.6.2.1 FOR HORIZONTAL WIND LOAD IS TAKEN FROM THE 2003 IBC. CALCULATE THE LATERAL WIND LOAD USING THE 2006 IBC, AND REVISE CALCULATIONS AS REQUIRED (SHEETS 16-29). 2. STRUCTURAL CALCULATIONS; SHEET 1: PROVIDE A REFERENCE ON SHEET 1 TO THE CURRENT ASCE MANUAL USED IN THE SEISMIC CALCULATIONS. 3. STRUCTURAL CALCULATIONS; SHEET 4: DID NOT LOCATE BEAMS B27 OR B28 ON SHEET 4. PROVIDE. 4. SHEET 9 (ROOF FRAMING PLAN); STRUCTURAL CALCULATIONS (SHEET 5): THE FRAMING PLAN INDICATES PRE-FAB TRUSSES AT THE ROOF FRAMING, WHILE THE CALCULATIONS INDICATE LPI JOISTS. CLARIFY. 5. STRUCTURAL CALCULATIONS; SHEET 16: NO CALCULATIONS WERE LOCATED FOR THE LATERAL DESIGN OF W-1. PROVIDE. 6. STRUCTURAL CALCULATIONS; SHEETS 16 AND 21: THE CALCULATIONS INDICATE W-2 HAS A 4' LENGTH FOR LATERAL DESIGN. TWO EXTERIOR WALLS AT THE NOOK AREA (DESIGNATED SW-1A AND SW-5) ARE NOT 4' LONG. REVISE THE CALCULATIONS AND/OR DRAWINGS AS REQUIRED, AND CHECK THE HOLDOWNS FOR THESE WALLS. 7. STRUCTURAL CALCULATIONS; SHEET 16: NO CALCULATIONS WERE LOCATED FOR THE LATERAL DESIGN OF W-3. PROVIDE. 8. STRUCTURAL CALCULATIONS; SHEETS 16 AND 22: THE CALCULATIONS INDICATE W-4 HAS A 21' LENGTH FOR LATERAL DESIGN WITH HPAHD22 HOLDOWNS EACH END. REVIEW AND REVISE SHEET 9 OF THE PLANS TO MATCH THIS DESIGN. 9. STRUCTURAL CALCULATIONS; SHEET 16: NO CALCULATIONS WERE LOCATED FOR THE LATERAL DESIGN OF W-5 AND W-6. PROVIDE. 10. STRUCTURAL CALCULATIONS; SHEET 16: NO CALCULATIONS WERE LOCATED FOR THE LATERAL DESIGN OF W-9 AND W-10. PROVIDE. 11. STRUCTURAL CALCULATIONS; SHEET 16: IT IS NOT CLEAR ON SHEET 9 OF THE PLANS HOW LONG WALL W-11 IS. THE CALCULATIONS INDICATE 20', BUT SHEET 9 DOES NOT SHOW A 20' WALL. REVISE THE CALCULATIONS AND/OR DRAWINGS AS REQUIRED. 12. STRUCTURAL CALCULATIONS; SHEET 16: NO CALCULATIONS WERE LOCATED FOR THE LATERAL DESIGN OF W-12. PROVIDE. 13. STRUCTURAL CALCULATIONS; SHEETS 16 AND 27: THE CALCULATIONS INDICATE W-14 HAS AN 8' LENGTH FOR LATERAL DESIGN. THIS WALL IS NOT 8' LONG. REVISE THE CALCULATIONS AND/OR DRAWINGS AS REQUIRED. 14. STRUCTURAL CALCULATIONS; SHEETS 16 AND 28: THE CALCULATIONS INDICATE W-15 HAS A 6' LENGTH FOR LATERAL DESIGN. REVIEW THE DESIGN FOR THE SOUTH WALL, WHICH IS NOT 6' LONG. REVISE THE CALCULATIONS AND/OR DRAWINGS AS REQUIRED. 15. GENERAL: PROVIDE WRITTEN RESPONSES FOR ALL REVIEW COMMENTS. |
| 02/03/2010 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS T10CM00023 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2006 International Energy Conservation Code, and Arizona State amendments to the 2006 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: All corrections and revisions shall be made on original tracings or a finished reproducible set. Return two sets along with a set of the first submission for reference. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. (Do not cloud the changes made for comment revisions). Incorporate changes on originals and provide two copied sets for review. All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. The City of Tucson adopted the 2006 IRC with amendments on 6/12/2007 and the 2006 UPC with amendments on 7/10/2007. Effective 1/1/2007 the Inclusive Home Design; starting 3/1/2009 Solar Water Preparation and 7/1/2009 Solar Photo-Voltaic Preparation are required for all new SFR and duplex plans. Show the code references on the plans. Amendments to adopted codes are at the City web-site http://www.tucsonaz.gov: Planning, Building, & Business; under the Building topic; Building Ordinances and Codes; Building Codes GENERAL NOTES: " Show compliance with the Inclusive Home Design Ordinance adopted by the City of Tucson on 10/16/2007. Notate accessible route, minimum door width, changes in floor elevation, door hardware, electrical outlet reach range, grab bar reinforcement, etc. " All SFR and Duplex plans submitted after March 1, 2009 require a solar water system, or future installation preparation City of Tucson Ordinance #10549 with one of the following provisions: ½"control conduit and two ¾" copper piping for water with rooftop termination; straight 3" metallic sleeve; or an accessible attic (clear path 30" wide x 30" high) over the water heater. Show appropriate notation. " All SFR and Duplex plans submitted after July 1, 2009 require a solar photo-voltaic system, or future installation preparation City of Tucson Ordinance #10549 with the following provisions: 1. A 4 square feet area for (meter, disconnect & inverter) equipment adjacent to the electrical service panel or near the proposed collector panel space. 2. The best roof space available for accommodating PV solar collector panels with capacity for collector dead loading (typically 4 lbs/SF). 3. A minimum 3,800 volt-ampere PV electrical load entry on the Service Load Calculation (Show as a continuous load of 15.8 A). 4. An Electrical Panel Schedule with a 240 volt circuit breaker space labeled "reserved for Photo Voltaic". Show appropriate notation. SITE PLAN: 1. Show compliance with the Pool Barrier requirement by including a barrier between the addition (openings) door/windows and the pool, if the pool is not enclosed with a 5' barrier, 2006 IRC Appendix G (Amendment). FOUNDATION PLANS: 1. Show compliance with termite treatment, R320 as amended. STRUCTURAL PLANS: 1. Note a proposed location and weight of future Solar Panel loads on the roof framing plan for verifying the truss load carrying capacity used for the engineered truss design, M1401. SECTIONS - DETAILS: 1. Show the ceiling gypsum board as either 5/8" or ½" sag resistant when applied to 24" o/c ceiling framing, IRC table R702.3.5 footnote d. 2. Show an exterior wall framing detail with a 2" weep screed clearance above floor level at the main entrance if designated as the accessible route, R703.6.2.1. Or, show a ramped passage at the garage tire stop for the Accessible route area. 3. Note and specify the stucco ICBO evaluation report number (with the vapor barrier system) on the plans, R703.6. 4. Show compliance with R806.4 by stating "no vapor retarders at the ceiling" for roofs without vented attic space. PLUMBING PLANS: 1. Show the code version recognized by the City of Tucson, 2006 UPC at Plumbing Note #1 sheet P1. 2. Provide water hammer arresters wherever quick-closing valves are installed in a water distribution system. The devices should conform to ASSE 1010-2004. Water hammer arresters are required for clothes washer, dishwasher and refrigerator water connections, UPC 609.10. 3. Provide an isometric drawing of each of the four 1" water supply branch lines with no more than 15 fixture units. UPC 610.8, Table 6-6. 4. Show an upper terminal cleanout at each horizontal drainage pipe greater than 5' (all drains with a sink) for Bath #2, UPC 707.4. The 2" VTR is undersized for this purpose. 5. Show a provision for a future solar water system, City of Tucson Ordinance #10549. MECHANICAL PLANS: 1. Show supply and return ducts with minimum R-8 insulation (includes vented attics) except when completely located inside the thermal envelope, R1103.2.1. Show R-4.2 insulation when ducts are located in an unconditioned space (chase) inside the thermal envelope, IECC 503.2.7 (City of Tucson Amended). 2. Provide return air duct and register sizes meeting minimum requirements of 72 SQ IN/ ton, M1602. Minimum duct/register size: heat pump or air conditioner - 6 SQ IN per 1,000 BTU, M1403.1 (1 ton cooling = 12,000 BTU). Enlarge the undersized 18" flex duct section on the 5 ton return duct. Enlarge the undersized 16" flex duct section on the 3.5 ton return duct. ELECTRICAL PLANS: 1. Add a double breaker space for future Photo Voltaic on the panel schedule, E3304.11 & E3606.2. 2. Show the location of a typical electrical panel on the Electrical Plan with 4 square feet of clear area for future Photo Voltaic equipment, E3501.6.2 & E3605.8. 3. Revise the electrical load calculation showing a minimum 3,800 volt-ampere or 16 Ampere 100% entry for future Photo Voltaic equipment, E3502.2. 4. Provide a panel schedule showing the general description, E3304.11. Clarify circuit #4 Mud room and #24 Study. 5. Show the location of each outlet on the Electrical Plan, E3305.1. Show circuit #10, 18, M17, M25, M31, column step lights and the outlet for the stack washer/dryer. 6. Clarify the circuit numbers for the dryer, oven, cooktop and Pantry light, E3603.5. 7. Clarify the subpanel feeder conductor size, E3605.5. The riser diagram is not consistent with the panel schedule. 8. Show one 20 AMP branch circuit in the laundry area; this circuit shall not serve other locations, E3603.3 and 3801.8. Separate from kitchen. 9. Show at least one wall switch controlled light or outlet in all habitable rooms, E3803.3. Include the Laundry room. OUTDOOR LIGHTING CODE 1. Clarify compliance with City of Tucson Outdoor Lighting Code; the total property lighting limit for area E3 (rather than E3a) is 55,000 lumens per acre and the unshielded limit for area E3 is 12,000 lumens per acre. 2. The Fixture "F" appears as an adjustable fixture. Full cut-off fixtures have no emittance above the nadir (fixtures are completely closed above and to the lowest point of the lamp). Revise the fixture style showing unshielded or provide a manufacturer's spec sheet showing a non-adjustable full cut-off style. INTERNATIONAL ENERGY CONSERVATION CODE: 1. Show the "R" values of insulation and the maximum "U" factors of the windows and doors on the plans consistent with the values appearing on the Res Check report, N1101.2. If you have any questions please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/05/2010 | CPIERCE1 | OUT TO CUSTOMER | Completed |
| 02/05/2010 | SUE REEVES | REJECT SHELF | Completed |