Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T10BU01685
Parcel: 136100930

Review Status: Completed

Review Details: WALLS - SUBMITTAL

Permit Number - T10BU01685
Review Name: WALLS - SUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/22/2010 ANDREW CONNOR NPPO REVIEW Passed
12/13/2010 MICHAEL ST. PAUL ZONING REVIEW Denied Provide the stamped approved Development Plan (DP). Be certain that the retaining walls are located on the DP and identify the retaining and overall height of each wall.

You may use the approved DP as your site plan for the retaining walls.
12/15/2010 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Denied 1. SHEET C9.6; RETAINING WALLS "C" AND "D": PROVIDE INFORMATION FOR THE DESIGN HEIGHT "H" ON THE DETAILS.
2. SHEET C9.6; RETAINING WALL "C": PROVIDE A DIMENSION FOR THE DEPTH OF THE KEY.
3. SHEET C9.7; RETAINING WALL "A" SECTION: PROVIDE A DETAIL ON THESE DRAWINGS FOR THE SAFETY RAIL.
4. SHEET C9.7 (RETAINING WALL "B" SECTION); STRUCTURAL CALCULATIONS: THE CALCULATIONS WALL DETAIL INDICATES 8'-0" FROM THE TOP OF THE FOOTING TO FINISH GRADE, WHILE THE DRAWING DETAIL INDICATES 7'-0". CLARIFY AND REDESIGN AS REQUIRED.
5. SHEET C10.2; TYPICAL LIGHTING POLE BASE: IS THIS TO BE INCLUDED IN THIS PERMIT? IF SO, PROVIDE STRUCTURAL DESIGN FOR THE POLE BASE AND FOUNDATION.
6. GENERAL: PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS.
12/17/2010 LOREN MAKUS ENGINEERING REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
01/04/2011 CINDY AGUILAR OUT TO CUSTOMER Completed
01/04/2011 SUE REEVES REJECT SHELF Completed