Permit Review Detail
Review Status: Completed
Review Details: WALLS - SUBMITTAL
Permit Number - T10BU01685
Review Name: WALLS - SUBMITTAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
11/22/2010 | ANDREW CONNOR | NPPO | REVIEW | Passed | |
12/13/2010 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | Provide the stamped approved Development Plan (DP). Be certain that the retaining walls are located on the DP and identify the retaining and overall height of each wall. You may use the approved DP as your site plan for the retaining walls. |
12/15/2010 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. SHEET C9.6; RETAINING WALLS "C" AND "D": PROVIDE INFORMATION FOR THE DESIGN HEIGHT "H" ON THE DETAILS. 2. SHEET C9.6; RETAINING WALL "C": PROVIDE A DIMENSION FOR THE DEPTH OF THE KEY. 3. SHEET C9.7; RETAINING WALL "A" SECTION: PROVIDE A DETAIL ON THESE DRAWINGS FOR THE SAFETY RAIL. 4. SHEET C9.7 (RETAINING WALL "B" SECTION); STRUCTURAL CALCULATIONS: THE CALCULATIONS WALL DETAIL INDICATES 8'-0" FROM THE TOP OF THE FOOTING TO FINISH GRADE, WHILE THE DRAWING DETAIL INDICATES 7'-0". CLARIFY AND REDESIGN AS REQUIRED. 5. SHEET C10.2; TYPICAL LIGHTING POLE BASE: IS THIS TO BE INCLUDED IN THIS PERMIT? IF SO, PROVIDE STRUCTURAL DESIGN FOR THE POLE BASE AND FOUNDATION. 6. GENERAL: PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
12/17/2010 | LOREN MAKUS | ENGINEERING | REVIEW | Approved |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
01/04/2011 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
01/04/2011 | SUE REEVES | REJECT SHELF | Completed |