Permit Review Detail
Review Status: Completed
Review Details: GRADING
Permit Number - T10BU01330
Review Name: GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/10/2010 | LOREN MAKUS | ENGINEERING | REVIEW | Denied | September 13, 2010 T10BU01330 T10OT01793 Grading and Floodplain review. 1. The Developed Flood Limit Line must be shown on the grading plan. 2. The label for the water harvesting basin references a detail on Sheet 4. Please revise. 3. Clearly label the areas to be over-excavated in accordance with the Geotechnical Engineering Report. 4. Provide general dimensions on the grading plan for all features such as parking spaces, the solid waste enclosure, curb radii, sidewalks and buildings. 5. Provide bollards or other means to prevent vehicles from driving into the unpaved areas of the site. 6. Clearly label and dimension the loading zones. 7. Provide labels and dimensions for landscape/planting islands. 8. There are two callouts for section B/3. The two areas are not similar enough to be represented by the same detail. Please provide additional details and callouts as necessary. 9. The SWPPP and floodplain use permit will be approved with the grading plan. Loren Makus, EIT Loren.makus@tucsonaz.gov |
| 09/10/2010 | TERRY STEVENS | ZONING | REVIEW | Denied | The development plan must be approved before the grading plan can be approved. |
| 09/20/2010 | ANDREW CONNOR | NPPO | REVIEW | Denied | Submit a copy of the approved Development Plan including landscape and native plant preservation plans for reference. Ensure that all Engineering comments and concerns are addressed. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/28/2010 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 12/28/2010 | SUE REEVES | REJECT SHELF | Completed |