Permit Review Detail
Review Status: Completed
Review Details: WALLS SUBMITTAL
Permit Number - T10BU00924
Review Name: WALLS SUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/17/2010 | ANDREW CONNOR | NPPO | REVIEW | Approv-Cond | |
| 06/21/2010 | JASON GREEN | ENGINEERING | REVIEW | Denied | DATE: June 21, 2010 SUBJECT: 450 S Toole Ave- Site Plan Engineering Review TO: Metro Permits LOCATION: T14S R13E Sec13 Ward 5 REVIEWERS: Jason Green, CFM ACTIVITY: T10CM01251 (Site/Building Plan), T10CM01551 (Building Plan) and T10BU00924 (Building Plan) SUMMARY: Engineering Division of Planning & Development Services Department has received and reviewed the revised Site and Building Plans for the above referenced property. Engineering Division does not recommend approval of the Site/Building Plan applications at this time. The following items need to be addressed: SITE PLAN COMMENTS: 1) DS 2-02.2.1.A.12: It has been determined by the Zoning Administrator that the requirements of LUC Section 3.3.7.3 for surfacing requirements does not need to be meet for the proposed driveway. However construction details must be provided on the plans for the construction of the 20-foot access road. Provide the following in plan view and/or details: a. Provide a detail for the transition from existing asphalt to proposed gravel driveway to prevent damage to the existing asphalt driveway. Label and dimension any cut off walls or other erosion control for the transition. b. Provide a cross section through the proposed driveway labeling thickness, gravel size, erosion control abatement if applicable, etc. c. Provide a note on the plan set to state; "All damage to existing asphalt due to construction will be repaired prior to final inspection of the site. 2) Provide the Docket and Page information for all existing easements as shown on site. All new easements will require Docket and Page information prior to final inspection of the site. GENERAL COMMENTS: Please provide a revised plan set that addresses the comments provided above. Include a comprehensive response letter and any supplemental information addressing in detail responses to all of the above comments. Enclose "redlines" with the resubmittal package. Further comments may be generated upon resubmittal of the plan review. For questions or to schedule an appointment I can be reached at 837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division Planning & Development Services Department |
| 06/21/2010 | STEVE SHIELDS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: ViaSat T10CM01251, T10CM01551, T10BU00924 Building Plan (1st Review) TRANSMITTAL DATE: June 21, 2010 1. The building plan has been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed. 2. Zoning could not verify that the building and wall permits were was in compliance with the approved site plan.. Please submit two copies of the approved and stamped site plan with the next building plan submittal. 3. Zoning will re-review the building plan on the next submittal to insure compliance with the approved and stamped site plan. Additional comments may be forthcoming. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 C:\planning\grading\t10cm01257.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: |
| 06/23/2010 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Denied | Please provide structural calculations for the 8' high masonry wall. |
| 06/23/2010 | RONALD BROWN | BUILDING-RESIDENTIAL | REVIEW | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/12/2010 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 07/12/2010 | SUE REEVES | REJECT SHELF | Completed |