Plan Number: T09SE00006
Parcel: Unknown

Address:
3390 S 6TH AV

Review Status: Completed

Review Details: REZONING - ZE HEARING

Plan Number - T09SE00006
Review Name: REZONING - ZE HEARING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/04/2009 TERRY STEVENS ZONING REVIEW Completed CDRC TRANSMITTAL

TO: Development Services Department
Rezoning Section

FROM: Terry Stevens
Lead Planner

PROJECT: Cricket - 6th Av
3390 S. 6th Ave. ---C-2 zoning
Special Exception Case Number - SE-09-06

TRANSMITTAL: October 7, 2008
1. The proposed use falls under the LUC Sec. 2.5.4.3 Special Exception Land Uses, Commercial Services Use Group, Sec. 6.3.5. Communications "31", subject to: Sec. 3.5.4.20.B, .C, and .E.1, or Sec. 3.5.4.20.B, .C, and .E.2, or Sec. 3.5.4.20.B, .C, and .F.2, or Sec. 3.5.4.20.B, .C, and .G
Development designator "31" requires or allows the following:
Minimum site required = 0 sq. ft
Floor area ratio = 0.90
Lot Coverage = N/A
Maximum building height = 40 feet
Interior perimeter yard indicator = DD

Zoning has reviewed this proposal for compliance with The City of Tucson Development Standard Land Use Code (LUC).

Off-Street Parking: One technician parking space required.
Off-Street Loading: 0 required
Bicycle Parking: 0 required
Pedestrian Access: Not required.


If you have any questions about this transmittal, please call Terry Stevens, (520) 836-4961 or email Terry.Stevens@tucsonaz.gov.
05/04/2009 JULIE YBARRA SIGNS SIGN CODE REVIEW Completed the above referenced case is located in the General Business District of the Tucson Sign Code. However, since this is a cell tower, there will be no sign permits issued to this site for the cell tower.
05/04/2009 JIMHOFF1 DOT ENGINEERING REVIEW Completed No objections.
Andy Dinauer
05/04/2009 DAVE MANN FIRE REVIEW Approved
05/04/2009 JUDITH IMHOFF COMMUNITY PLANNING REVIEW Completed DEPARTMENT OF URBAN PLANNING & DESIGN
SE-09-06 Cricket - 6th Avenue
C-2 Special Exception
General Plan
04/25/09 drcorral

The proposed special exception land use is for the co-location of a Cricket wireless telecommunications antena to an existing cellular communications facility, Sprint, located near the western side of the Southgate Shopping Center and south of I-10 at 3390 S. 6th Avenue. The site is zoned and is surrounded by C-2 zoning.

Policy Summary

The General Plan provides land use guidance for the subject, with the Design Guidelines Manual providing additional design guidance.

Both the General Plan and the Design Guidelines Manual support the requested use when visual appropriate design elements and buffering techniques are used to mitigate any potential negative impacts of more intense development on established neighborhoods and public views.

Discussion

The site is a reasonable fit for the proposed telecommunications facility. Although it is readily visible to the general public, the proposed location and stealth design are in keeping with the intent of these Plans.

The proposal is to extend the existing pole by 15 feet resulting in a maxim height of 79.2 feet. The six existing antennas at the 50-foot- centerline will be relocated to the 76.2-foot centerline of the pole extension above the existing Sprint antennas. Each antenna will have a maximum size of 16-inches by 6-feet by 6-inches. The design will be in a cluster mount which will provide less mass than a typical T-Arm design and will be smaller in appearance then the exiting wireless communications provider's antennas and mounts. The ground equipment area will remain unchanged. To create a stealth design, staff will be placing a condition that monopole to be painted with non-reflective paint in a color that matches the surrounding environment. Doing so will allow monopole to blend in with the surroundings, and therefore, not conflict with Plan policies.

Recommendation

The proposed special exception land use for the co-location of an unmanned Crickett wireless telecommunications facility located near the western side of the Southgate Shopping Center and south of I-10 at 3390 S. 6th Avenue can be supported. The proposal appears to be in general compliance with the policy and intent of the General Plan and the Design Guidelines Manual. The following conditions are recommended to further the proposal's compliance with the General Plan and Design Guidelines Manual:

1) The monopole is to be painted with non-reflective paint to match and be compatible with the surrounding environment and adjacent structures.
Relevant Policies
· GP Element 4, Policy 3.7
· DG I.B.3.f
· DG I.B.2.e

2) The monopole is to be no higher than 79.2 feet.
Relevant Policies
· GP Element 4, Policy 3.7
· DG I.B.3.f
· DG I.B.2.e

Plan Policy

General Plan

Element 4: Community Character and Design
Policy 3: Preserve scenic view of natural features and community landmarks

3.7 Require that, whenever possible, telecommunications facilities be located, installed, and maintained to minimize visual impact, preserve views, and be consistent with the City's adopted land use plans and policies. Cabling and fiber optics should be installed underground where possible, and visual impact of cellular towers will be prime consideration in the City's acceptance and approval.

Policy 5: Promote neighborhood identity and visual character

5.5 Promote upgrades to neighborhood infrastructure, including sidewalks and street lighting, and improvements to the existing housing stock.

5.5.A Consider incentive for telecommunications providers to install infrastructure, not only in newer areas, but also in older neighborhoods to increase opportunities for all citizens to have access to high-tech telecom services.

Design Guidelines Manual

e. Design Context and Neighborhood Character (1.B.2.e)
Intent - Improve the character of new projects and reinforce existing architectural character in established neighborhoods.

Solution - Harmonize new buildings with existing buildings by incorporating design elements of the adjacent architecture including the following:
· Scale and massing of structure
· Finishes, materials, and colors
· Site amenities such as walls and landscaping




s:\caserev\sp-excpt\se08-09\ SE-09-06 Cricket - 6th Avenue.doc
05/06/2009 ANDY VERA ENV SVCS REVIEW Completed ES has no objections to this re-zoning request as it pertains to solid waste disposal.
05/06/2009 MATT FLICK ENGINEERING REVIEW Completed DSD Engineering has no objection or adverse comment to the approval of a Special Exception for the proposed extension of the cell tower.

The existing cellular communication site lies near the western side of the Southgate Shopping Center (D08-0005). Access will be from the Southgate Shopping Center parking area access lanes. The site does not lie within a mapped 100-year floodplain; detention/retention has been addressed with the Southgate Shopping center development plan.

No conditions are requested.


Matt Flick, P.E.
Development Services Department
City of Tucson

Phone: (520) 837-4931
Fax: (520) 791-4340

Please visit our web site: www.ci.tucson.az.us/dsd
05/08/2009 JOE LINVILLE LANDSCAPE REVIEW Approved
05/08/2009 JIMHOFF1 REZ AGENCY REVIEW PIMA ASSN OF GOVTS Completed CASE: SE-09-06 Cricket - 6th Ave, C-2 Zone (Ward 5)

COMMENT: NO OBJECTIONS OR ADVERSE COMMENTS

Vehicle Trip Generation: Not Available

Please call if you have questions or need additional information.

Thanks
KoSok Chae, Ph.D.
05/15/2009 JOSE ORTIZ DOT TRAFFIC REVIEW Completed TDOT-Traffic has no objections to this special exception
05/19/2009 JIMHOFF1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed Water Assurance letter received May 1, 2009.
05/19/2009 JIMHOFF1 REZ AGENCY REVIEW PIMA CNTY WASTEWATER Completed
05/19/2009 JIMHOFF1 REZ AGENCY REVIEW SCHOOL DISTRICT Completed
05/19/2009 NSTEVEN1 REZ AGENCY REVIEW ADOT Completed No comment received.
05/19/2009 NSTEVEN1 REZ AGENCY REVIEW TDOT RTA Completed No comment received.
05/19/2009 JIMHOFF1 REZ AGENCY REVIEW TDOT STREETS Completed 5/15/09
No objections from Streets

Sandra Zurbrick
05/19/2009 JIMHOFF1 REZ AGENCY REVIEW OTHER AGENCIES Completed TEP has no comment on this case.

Sincerely,

Laura J. Pinnas
Environmental and Land Use Planner
Land Management
Tucson Electric Power Company
PO Box 711, Mail Stop DS315
Tucson, AZ 85702
(520) 918-8254
FAX (520) 545-1435
lpinnas@tep.com
05/19/2009 JIMHOFF1 REZ AGENCY REVIEW OTHER AGENCIES Completed I have no problem with this request.
CSO Becky Noel #37968
Tucson Police Dept
05/19/2009 JIMHOFF1 REZ AGENCY REVIEW OTHER AGENCIES Completed May 11, 2009

Ms. Imhoff:

Thank you for the opportunity to comment on SE-09-06 Cricket - 6th Avenue, a special exception application for a site located south and east of the southeast corner of 40th Street and 10th Avenue. The purpose of this application is to allow for the increase in height of an existing telecommunications facility.

This site is within the Tucson International Airport public disclosure area and traffic pattern airspace. The site is not within the City of Tucson Airport Environs Zone.

The Tucson Airport Authority requests the following condition of rezoning approval:

"That prior to the City's approval of any building permit, the property owner shall record an avigation easement. The easement recognizes the existence, and operational characteristics of the Tucson International Airport and further conveys the right to the public to lawfully use the airspace above the property. The content of such documents shall be
according to the form and instructions provided, which have been reviewed and approved by the City Attorney."

The Tucson Airport Authority also asks that the property owner forward a copy of the recorded avigation easement to:

Jordan D. Feld, AICP
Director of Planning
Tucson Airport Authority
7005 S. Plumer
Tucson, AZ 85756

Again, thank you for the opportunity to comment on the subject application and the City of Tucson's recognition of the regional importance in ensuring continuing safety and viability of Tucson International Airport.

Respectfully,

Jordan D. Feld, AICP
Director of Planning
Tucson Airport Authority
7005 S. Plumer Ave.
Tucson, AZ 85756
05/19/2009 JIMHOFF1 REZ AGENCY REVIEW OTHER AGENCIES Completed I have no comment on this case.
Greg Saxe
Pima County
Regional Flood Control
05/19/2009 JIMHOFF1 REZ AGENCY REVIEW PARKS & RECREATION Completed DATE: May 05, 2009

SUBJECT: SE-09-06 Cricket - 6th Ave, C-2 Zone (Ward 5)

Staff has reviewed the proposed rezoning and recommends the following requirement:

The subject antenna will be very visible from the future Julian Wash Greenway to the south. Therefore, the antenna should be camouflaged as, for example, a palm tree.

Glenn Hicks
Parks and Recreation
791-4873 ext. 215
Glenn.Hicks@tucsonaz.gov
05/19/2009 JIMHOFF1 REZ AGENCY REVIEW OFFICE OF CONSERVATION & SUSTAINABLE DEVELOPMENT Completed