Permit Number: T09SA00315
Parcel: 11931022Q

Review Status: Completed

Review Details: LUCAPPS - OVERLAY ZONE REV

Permit Number - T09SA00315
Review Name: LUCAPPS - OVERLAY ZONE REV
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/08/2009 ANDREW CONNOR LANDSCAPE REVIEW Denied 1) The proposed natural area as it pertains to HDZ review must be designated by legal description on a document recorded with the Pima County Recorder for a lot division or a natural area may be designated as a deed-restricted portion of a privately-owned lot or as a separate parcel. LUC 2.8.1.7 Include the recording information on the Final Plat.

2) To protect the natural areas, covenants which run with the land will be provided in favor of the City of Tucson and of all owners with record interest in the natural area. LUC 2.8.1.7

3) Identify the natural area as NUOS on the Final Plat and on the recorded documents and covenants. LUC 3.8.6.4.B
12/09/2009 TERRY STEVENS ZONING REVIEW Approved
12/10/2009 LOREN MAKUS ENGINEERING REVIEW Denied December 10, 2009
T09SA00315
Hillside Overlay Review

1. The Average Cross Slope analysis doesn't appear to be correct. When a natural area is designated, that area must be excluded from the ACS calculation. The ACS (less natural area) must be revised so that the denominator of expression excludes the natural area. (LUC 2.8.1.6 A.2)
2. When the existing house was constructed, the area disturbed by grading and construction activities exceeded the area shown as developable area on the exhibit. The disturbed area may have to be mitigated before the plat is approved.
3. Clearly indicate that the graded slope areas are included in the gradable area.
4. Discuss how the cut slopes on proposed lot 3 meet the requirements of Development Standard 9-01.5.B.
5. Grading Permit T04BU00547 is expired. Grading in accordance with this permit must be completed, inspected and approved before the subdivision is approved.
12/17/2009 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

December 17, 2009

Adam Edwards, P.E.
AMEC
3275 West Ina Road, Suite 165
Tucson, Arizona 85741

Subject: T09SA00315 Hillside Development Overlay Zone for 333 West Mockingbird Lane (S09-072)

Dear Adam:

Your submittal of November 9, 2009 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter for each agency explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

3 Copies Revised Overlay Zone submittal package as detailed in the on line comments (Engineering, Landscape, DSD).



THE PUBLIC COMMENT PERIOD WILL BE OPENED WITHIN THE NEXT TWO WEEKS.





Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 219-0499