Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T09SA00178
Parcel: 10509546C

Address:
68 W RIVER RD

Review Status: Completed

Review Details: LUCAPPS - OVERLAY ZONE REV

Permit Number - T09SA00178
Review Name: LUCAPPS - OVERLAY ZONE REV
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/29/2009 FRODRIG2 ZONING REVIEW Denied TO: Development Services Department Plans Coordination Office
FROM: Steve Shields
Lead Planner

PROJECT: Quick Trip Store 1450
T09SA00178
Overlay Zone Review (1st Review)

TRANSMITTAL DATE: July 9, 2009

DUE DATE: July 23, 2009

COMMENTS:
1. This development is subject to the review and approval of the special application for the Scenic Corridor Overlay. Provide a general note stating: "The Special application case number is T09SA00178.The special application has been reviewed and approved, approval date __________, without conditions."

2. LUC Sec. 2.8.2.3.C Add the 400-foot SCZ corridor boundary from River Road on site plan. Zoning acknowledges that the 400-foot SCZ corridor boundary from River Road is off site provide a dimension to the line and show as not to scale.

3. LUC Sec. 2.8.2.4.A Label the required thirty (30) foot buffer as "30 FOOT UNDISTURBED NATURAL BUFFER TO BE PRESERVED AND MAINTAINED IN IT'S NATURAL STATE".

4. LUC Sec. 2.8.2.6.B Provide the view corridor calculation on the plan.

5. Please add the following notes to the site plan.
a. Maximum height of structures will be 1/3 the distance of the structure from the future right-of-way of River Road, not to exceed 30 feet for commercial development from design grade.

b. No grading beyond what is necessary for siting of buildings, drives, private yards, and structural improvements. All viable vegetation with a caliper of 4 inches or greater and all saguaro cacti will be preserved or relocated on the site per the Native Plant and Preservation Ordinance.

c. All new utilities for development on private property or public right-of-way along River Road will be underground. Trenching is permitted for the placement of utilities lines, if area is revegetated in accordance with Land Use Code Sec. 3.7.5.2.D

d. Building or structure surfaces, which are visible from River Road will have colors, which are, predominate within the surrounding landscape such as desert and earth tones.

e. Fencing and freestanding walls facing River Road. will meet material restrictions in Land Use Code Sec. 3.7.3, Screening Requirements.

f. All areas between the MS & R right-of-way line and the existing street right-of-way that are disturbed by development shall be revegetated with native vegetation.

g. All disturbed areas on the site that are visible from River Road and are not covered by permanent improvements shall be revegetated with native plants, plants from the Drought Tolerant Plant List, or a combination of both.

6. Provide the overlay number T09SA00178 in the lower right hand corner, near the title block on all sheets of the development plan.

7. The proposed vehicle parking spaces located along the south property line may not be located within the 30' Scenic Corridor buffer.

8. All requested information will be provided on the development plan or as attachments to the development plan

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.com
07/29/2009 FRODRIG2 LANDSCAPE REVIEW Approved
07/29/2009 FRODRIG2 ENGINEERING REVIEW Approved
07/29/2009 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

July 29, 2009

Michael Marks, AICP
MJM Consulting, Inc.
7002 East 4th Street
Tucson, Arizona 85710

Subject: T09SA00178 Scenic Corridor Overlay Zone for 68 West River Road (D09-0013)

Dear Mike:

Your submittal of June 24, 2009 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter for each agency explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

2 Copies Revised Overlay Zone submittal package as detailed in the on line comments (Zoning, DSD).



THE PUBLIC COMMENT PERIOD WILL BE OPENED WITHIN THE NEXT TWO WEEKS.





Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/


Via fax: 885-5021