Plan Review Detail
Review Status: Completed
Review Details: PIA RESUBMITTAL
Plan Number - T09PI00006
Review Name: PIA RESUBMITTAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
03/29/2010 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Denied | Waiting on MOU for maintenance agreement. Need legals for irrigation easements on public roads. |
04/08/2010 | RLEIGH1 | UTILITY CLEARANCES | COT STREETS DIVISION | Approved | |
04/08/2010 | LANCE PETERSON | DOT STREET MAINTENANCE | REVIEW | Approved | No objection pertaining to Street Maintenance. |
04/08/2010 | RLEIGH1 | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Approved | |
04/08/2010 | RLEIGH1 | UTILITY CLEARANCES | PC WASTEWATER MGMT | Approved | |
04/08/2010 | RLEIGH1 | UTILITY CLEARANCES | QUEST COMMUNICATION | Approved | |
04/08/2010 | RLEIGH1 | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Approved | |
04/08/2010 | RLEIGH1 | UTILITY CLEARANCES | COX COMMUNICATION | Approved | |
04/08/2010 | RLEIGH1 | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Approved | |
04/08/2010 | RLEIGH1 | UTILITY CLEARANCES | EL PASO NATURAL GAS | Approved | |
04/08/2010 | RLEIGH1 | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Approved | |
04/12/2010 | RICHARD LEIGH | DOT ENGINEERING | REVIEW | Denied | April 12, 2010 TO: DSD PIA Coordinator SUBJECT: Mountain Vail Estates, Part "G", Public Improvements, PIA T09PI00006 PROJECT REVIEWER: Richard Leigh, DOT, Permits and Codes Section RESUBMITTAL REQUIRED: Permits and Codes Section has reviewed the PIA Plan and does not recommend approval of the PIA Plan at this time. The following comments need to be addressed in the next submittal. 1. Sheet 4, Detail 8/4: Indicated in the detail 8/4 the bearing bars of the grate will be orientated perpendicular to vehicular travel (support bars spacing 3.48'). Will this orientation provide the structural integrity equal to as when the bearing bars are place parallel to vehicular traffic. Refer to redline plans for additional comments and comment details. If you have any questions, I can be reached at 837-6647 or Richard.Leigh@tucsonaz.gov |
04/20/2010 | JOSE ORTIZ | DOT TRAFFIC | REVIEW | Approv-Cond | April 20, 2010 ACTIVITY NUMBER: T09PI00006 PROJECT NAME: Mountain Vail Estates PROJECT ADDRESS: 11311 E Mary Ann Cleveland Wy PROJECT REVIEWER: Jose E. Ortiz PE, Traffic Engineer Resubmittal Required: Traffic Engineering recommends a conditional approval of the PIA Plan; therefore revisions are required prior to the submittal of mylars. The following items must be revised or added to the plan. Include a response letter with the next submittal that states how all comments have been addressed. 1. See redlines on sheets 3, 5, & 11 and address the redline comments. During the next submittal please re-submit the roll of redlines for back checking purposes. If preferred, prior to submitting mylars, send a PDF of the revised sheet and a copy of the redlines to verify acceptance by TDOT-Traffic. If you have any questions, I can be reached at 791-4259 x76730 or Jose.Ortiz@tucsonaz.gov |
04/21/2010 | RICHARD LEIGH | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSADOR | Completed | |
04/21/2010 | RICHARD LEIGH | PIA COORDINATOR | OUT TO CUSTOMER | Completed |