Plan Review Detail
Review Status: Completed
Review Details: PIA SUBMITTAL
Plan Number - T09PI00006
Review Name: PIA SUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/06/2009 | TAMI HAUSER | UTILITY CLEARANCES | COT STREETS DIVISION | Denied | PLEASE SUBMIT UTILITY CLEARANCE LETTERS. |
| 04/06/2009 | TAMI HAUSER | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Denied | PLEASE SUBMIT UTILITY CLEARANCE LETTERS. |
| 04/06/2009 | TAMI HAUSER | UTILITY CLEARANCES | PC WASTEWATER MGMT | Denied | PLEASE SUBMIT UTILITY CLEARANCE LETTERS. |
| 04/06/2009 | TAMI HAUSER | UTILITY CLEARANCES | QUEST COMMUNICATION | Denied | PLEASE SUBMIT UTILITY CLEARANCE LETTERS. |
| 04/06/2009 | TAMI HAUSER | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Denied | PLEASE SUBMIT UTILITY CLEARANCE LETTERS. |
| 04/06/2009 | TAMI HAUSER | UTILITY CLEARANCES | COX COMMUNICATION | Denied | PLEASE SUBMIT UTILITY CLEARANCE LETTERS. |
| 04/06/2009 | TAMI HAUSER | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Denied | PLEASE SUBMIT UTILITY CLEARANCE LETTERS. |
| 04/06/2009 | TAMI HAUSER | UTILITY CLEARANCES | EL PASO NATURAL GAS | Denied | PLEASE SUBMIT UTILITY CLEARANCE LETTERS. |
| 04/06/2009 | TAMI HAUSER | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Denied | PLEASE SUBMIT UTILITY CLEARANCE LETTERS. |
| 04/16/2009 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Denied | Submit a copy of your approved NPPO plan. Submit a copy of your site irrigation plan. |
| 05/04/2009 | LANCE PETERSON | DOT STREET MAINTENANCE | REVIEW | Denied | We have reviewed this plan and have the following comments: 1. Sheet 5 - Detail 3/5 - This detail calls out a fairly long flat pipe. We would like access for maintenance. 2. Sheet 7 - Sta 24+35 - For the maintenance of this pipe we would like ot have a manhole. Also, it is our understanding that the outlet of these pipes will be maintained by the homeowners association. Please verify this. 3. Sheet 8 - Similar concern at STA 13+07 as above. 4. All work in the right of way needs to be coordinated with Paul Rosenboom at 791-3154, ext. 234. HP & PR |
| 05/07/2009 | RICHARD LEIGH | DOT ENGINEERING | REVIEW | Denied | 6 May 2009 SUBJECT: Mountain Vail Estates, Part "G", Public Improvements, PIA T09PI0006 PROJECT REVIEWER: Richard Leigh, DOT, Permits and Codes Section RESUBMITTAL REQUIRED: Permits and Codes Section has reviewed the PIA Plan and does not recommend approval of the PIA Plan at this time. The following comments need to be addressed in the next submittal. 1. Include the plan number "I-2009-015" in title block of each sheet. 2. Include Development Services Department PIA activity number "T09PI00006"on cover sheet. 3. Sheet 3, Detail 1/3: Indicate proposed roadway cross slope. 4. Sheet 3, Detail 3/3: Indicate a minimum 5'x 5' landing for the proposed ramps 5. Sheet 4, Detail 9/4: Indicate proposed roadway cross slope and call out a maximum cross slope of 2% for the proposed asphalt path 6. Sheet 4, Detail 8/4: As indicated in the detail, the bearing bars of the grate will be orientated perpendicular to vehicular travel. Will this orientation provide the structural integrity equal to as when the bearing bars are place parallel to vehicular traffic? Additionally, indicate that the grates will be anchored per Standards Specifications for public improvements 503-3. 7. Sheet 5, Detail 5/5 & 6/5: Indicate proposed roadway cross slope. 8. Sheet 5, Detail 2/5: Indicate the placement of barricade railing and the class of reinforced concrete pipe. Additionally, Indicate that the hinge point of the slope must be a minimum of 2' from the property line. 9. Sheet 5, Detail 3/5: Delineate right-of-way and indicate the placement of barricade railing. 10. Sheet 8: Provide curve data and stationing for the cul-de-sac at the end of Granite Gulch Way. 11. Sheet 11: Provide post barricades and appropriate signage at the east end of Rincon Range Drive to restrict vehicular traffic. 12. Sheet 11: Provide erosion protection at end of pavement at the east end of Rincon Range Drive. 13. Provide line and curve data for roadway centerline. 14. Placement of private irrigation facilities within the right-of-way will require a private utility easement. Please contact the COT Real Estate Division for information on acquiring an easement. Additionally, private irrigation facilities must meet COT adopted standards. Note the following requirements to any proposed irrigation in the right-of way. Schedule 80 sleeving. Marking tape. Minimum 18" depth. Mark/stamp on curb - IS (Irrigation System) and/or placard at back of curb Sleeves must be in a recorded easement (easement width is dependent on what is needed for installation and/or repairs). Sleeve should extend beyond the right-of-way (into private property), unless otherwise approved by TDOT. 15. Verify that a 2' minimum set back is provided from the hinge point of any cut and fill slope on private property and the property line (City of Tucson Development Standard 11-09.0). 16. Provide barricade railing along the right-of-way of any slope steeper than 4:1 and deeper than two (2) feet. Note ending and beginning of any proposed barricade railing. 17. Verify that the cross slopes for pedestrian cross walk areas does not exceed 2%. 18. Add the following notes to the General Storm Drain Notes: Drainage pipe shall conform to PC/COT SSPI Section 501or as directed by the engineer. Pipe bedding shall conform to PC/COT Standard Detail 108. Refer to redline plans for additional comments and comment details. If you have any questions, I can be reached at 837-6647 or Richard.Leigh@tucsonaz.gov |
| 05/08/2009 | JOSE ORTIZ | DOT TRAFFIC | REVIEW | Denied | May 6, 2009 ACTIVITY NUMBER: T09PI00006 PROJECT NAME: Mountain Vail Estates PROJECT ADDRESS: 11311 E Mary Ann Cleveland Wy PROJECT REVIEWER: Jose E. Ortiz PE, Traffic Engineer Resubmittal Required: Traffic Engineering does not recommend approval of the PIA Plan; therefore a revised PIA Plan is required for re-submittal. The following items must be revised or added to the plan. 1. Include a response letter with the next submittal that states how all comments have been addressed. 2. See redlines on the submitted drawings and address the additional redline comments. During the next submittal please re-submit the roll of redlines for back checking purposes. 3. Install R1-1 (Stop Sign) with street names on Granite Gulch Way off of Orange Mallow Drive per PCDOT & TDOT Signing Manual (2002) Chap 5-11, 5-12, and Chap 9-2. 4. Parking is not allowed in cul-de-sacs from PRC to PRC. So indicate on the plans by showing no parking signs on the plans. (DS 3-01.0 fig 20) (straight cul-de-sac) 5. Provide a detail of the No Parking sign to be used. There is one attached to the red line plan set. 6. Place the PIA Case number on the cover sheet. 7. Add the following Signing General Notes 5(a) & 5(b) per PCDOT & TDOT Signing Manual (2002) (Chapter 1, Sheet 12) to the Plans. 8. Add the following Pavement Marking/Striping General Notes to the Plans: 'ALL STREET SIGNAGE TO BE COORDINATED WITH C.O.T. TRAFFIC ENGINEERING CALL 791-4259 A MINIMUM OF 48 HOURS PRIOR TO THE INSTALLATION OR REMOVAL OF ANY SIGNAGE OR STRIPING. ALL REQUIRED SIGNAGE WILL BE INSTALLED AT THE CONTRACTOR'S EXPENSE.. USE 2" SQUARE-TUBE POST AND SQUARE TUBE POST FOUNDATIONS FOR SIGNING. 'ALL NON-SIGNALIZED INTERSECTION STREET NAMES MUST HAVE E-W BLOCK NUMBER ADDRESSES FOR E-W ROADWAYS AND N-S BLOCK NUMBER ADDRESSES FOR N-S ROADWAYS.' 'THE CITY SHALL NOT BE LIABLE FOR ANY ERRORS AND/OR OMISSIONS ON THESE PLANS. ITEMS NOT MEETING CITY STANDARDS SHALL BE REPAIRED/REPLACED BY THE DEVELOPER/CONTRACTOR AND AT NO COST TO THE CITY.' If you have any questions, I can be reached at 791-4259 x76730 or Jose.Ortiz@tucsonaz.gov |
| 05/15/2009 | TAMI HAUSER | PIA COORDINATOR | CUSTOMER CALLED | Completed | |
| 05/15/2009 | TAMI HAUSER | PIA COORDINATOR | OUT TO CUSTOMER | Completed |