Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T09OT02229
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/16/2009 | LAITH ALSHAMI | ENGINEERING | REVIEW | Approved | Laith Alshami, Floodplain and Engineering Review. Floodplain Use Permit for "Costco Store #407 Parking Expansion". 12/16/2009 FLOODPLAIN USE PERMIT NO. T09OT02229 ADDRESS: 6255 East Grant Road Tucson, AZ 85712 PROPERTY OWNER'S NAME: Costco Wholesale Corporation The Developer/owner is authorized to use a portion of the flood hazard area in the City of Tucson near the property described as: Costco Store #407. A portion of Southeast Quarter of Section 36, T-13-S, R-14-E, G.&S.R.M., Pima County, Arizona, for the purpose of constructing a stone check dam and all associated excavation work and drainage structures, within a regulatory floodplain area as shown on the subject project Grading Plan, Case # T09BU01550 (see plans for additional details). The Developer/owner agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the Developer/owner. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit. The following conditions shall apply to this permit (Refer to Chapter 26 "FLOODPLAIN, STORMWATER AND EROSION HAZARD MANAGEMENT" for additional information): 1. All work shall conform to the subject project Grading Plan Case # T09BU01550 (see plans for additional details), which is made part of this permit. 2. The proposed structure shall be placed on an engineered pad, compacted to 95% density. 3. No fill shall be placed in any floodway; nor shall any fill be placed where it diverts, retards or obstructs the flow of water to such an extent that it creates a danger or hazard to life or property in the area. 4. The disturbed soil, around, underneath and behind the proposed structures, shall be treated based on the geotechnical engineer recommendations and shall be compacted to least 95% density. 5. The existing drainage patterns shall not be obstructed or diverted other than what is shown on the attached approved grading plan. 6. Within 5 (five) days of issuance of this permit, through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "Construction proceeding under requirements of City of Tucson Floodplain Use Permit No. T09OT02229. For more information please call 791-5550." 7. Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 8. This permit becomes invalid and is subject to additional floodplain review, if any required development permit (s') changes the configuration of the structure and or site development. This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions set forth in this permit are not complied with. Also, this permit will expire one year from its date of issue. Renewal of this permit might require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division. (EXPIRATION DATE) Month: 12 Day: 16 Year: 2010 APPLICANT NAME: Cardno WRG, Inc., Michael Pniewski ADDRESS: 9977 North 90th Street, Suite 350, Scottsdale, AZ 85258 PHONE NO.: (602) 977-8000 ________________________ _____________ APPLICANT'S SIGNATURE DATE The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions. |