Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T09OT01737
Parcel: 114551740

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T09OT01737
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/03/2009 BIANCA RAMIREZ ENGINEERING REVIEW Denied DATE: November 3, 2009
SUBJECT: Addition of Garage and Porch
TO: Sunny Hennig
LOCATION: 10238 E Desert Flower Place, T13S, R15E, Section 35, Ward 2
REVIEWERS: Bianca Ramirez, CFM
ACTIVITY: T09CM01709

RESUBMITTAL REQUIRED: Site Plan and Drainage Statement

SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed site plan and drainage statement for the above referenced property. Engineering Division does not recommend approval of the site plan or the drainage statement at this time. Please address the following review comments prior to the next submittal.

Please include a response letter to the comments along with the corrected copies of the site plan and drainage statement.

Site Plan:

1. Complied
2. Complied
3. Correctly show the limits of the 100-year floodplain and water surface elevation per D.S. 2-02.2.1.15.
Additional note: Identify the floodplain limits from the final plat and verify that location of existing residence has been correctly idenfitied on site.
4. Indicate cut & fill quantities on the site plan per D.S. 2-02.2.1.17
5. Indicate proposed finished floor elevation(s), and finished grades. DS Sec.2.02.2.1.A.16:
6. Complied
7. Provide legend and indicate all symbols on plans in legend.
8. Provide floodplain limits and erosion hazard setback limits on site plan per final plat. Provide floodplain limits per drainage report. Floodplain limits do not appear to be depicted correctly.
9. Draw the Final Plat lot boundaries with dimensions for all lines per the final plat and actual location of residence.
10. Per Floodplain Ordinance, Tucson Code Sec. 26-5.2.(4) Development in the floodway fringe shall not unnecessarily alter riparian habitats of watercourse and adjacent bank areas. Provide seal on the plan for engineering information regarding the location of the (floodplain limits).
11. Additional comments may be forthcoming.

Drainage Statement:

1. Scour protection must be tied into the existing erosion hazards setback structure (line) on both the upstream and downstream side of proposed development.
2. Complied
3. Complied
4. Acknowledged
5. Drainage report cannot be approved until ERR review has been completed.
6. Additional comments may be forthcoming.


Seal is required on the plan for engineering information (floodplain limits).


If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov

Bianca C. Ramirez
Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4928 office
(520) 879-8010 fax

Final Status

Task End Date Reviewer's Name Type of Review Description
11/09/2009 DELMA ROBEY OUT TO CUSTOMER Completed
11/09/2009 SUE REEVES REJECT SHELF Completed