Permit Review Detail
Review Status: Completed
Review Details: FLOODPLAIN
Permit Number - T09OT01298
Review Name: FLOODPLAIN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/30/2009 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Approved | June 30, 2009 FLOODPLAIN USE PERMIT # T09OT01298 PROJECT ADDRESS: 3201 S Park Ave APPLICANT'S NAME: Ashton Company Inc PROPERTY OWNER: KB Homes This parcel appears to be impacted by a City of Tucson identified 100-year floodplain. The applicant is authorized to use a portion of the flood hazard area in the City of Tucson, Arizona, on the property described as: 3201 S Park Avenue, Tucson, AZ 85713, IRR PCL LYG ADJ & NELY I-10 & W KINO BLVD 108.72 AC SEC 30-14-14. In a portion of Township 14 South, Range 14 East, Section 30, for installation of a temporary construction trailer. The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit. The following conditions apply to this permit: 1) This permit becomes invalid and is subject to additional floodplain review, if any required development permit changes the configuration of the improvement, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from development within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson. This parcel appears to be impacted by a City of Tucson determined 100-year floodplain. However, per the approved grading plan and drainage report indicate that the elevation of the ground surface just west of the proposed location of the construction trailer is between 2466 and 2467. The detention basin 100-year water surface elevation is 2464.70 per the grading plan. Per drainage report the floodplain limits have changed per the detention basin. 2) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T09OT01298 FOR INFORMATION PLEASE CALL 791-5550." 3) This Floodplain Use Permit is effective for 180 days. 4) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times. 5) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval. 6) See the associated activity T09CM01617. This Floodplain Use Permit will be automatically revoked and becomes invalid for non-compliance to conditions set forth in this permit. Also, this permit will expire one year from its date of issue. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division. (EXPIRATION DATE) Month: 12 Day: 30 Year: 2009 CONTRACTOR: Ashton Company Inc ADDRESS: 2727 S Country Club, Tucson, AZ 85712 PHONE: (520) 624-5500 OWNER: KB Homes ADDRESS: 238 S Craycroft, Tucson, AZ 85711 PHONE: (520) 918-6400 SIGNATURE OF APPLICANT DATE The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/30/2009 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |