Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: T09OT01100
Parcel: 140260370

Review Status: Completed

Review Details: FLOODPLAIN

Permit Number - T09OT01100
Review Name: FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/17/2009 LAITH ALSHAMI ENGINEERING REVIEW Approved Laith Alshami, Floodplain and Engineering Review. Floodplain Use Permit for "USDA Forest Service".

06/17/2009

FLOODPLAIN USE PERMIT NO. T09OT01100
ADDRESS: 2646 East Commerce Center Place
Tucson, AZ 85706

PROPERTY OWNER'S NAME: HAM Tucson, LLC.

The Developer/owner is authorized to use a portion of the flood hazard area in the City of Tucson near the property described as:

USDA Forest Service - Tucson I.O.C. A portion of "Block 2" of Tucson Airport Commerce Center, Book 51, of Maps and Plats Page 25, SECTION 8, T-15-S, R-14-E, G.&S.R.M., for the purpose of installing a retaining wall and all associated excavation work and drainage structures, within a regulatory floodplain area as shown on the subject project Grading Plan included in the Development Package #D09-0011 (see plans for additional details).

The Developer/owner agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the Developer/owner. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

The following conditions shall apply to this permit (Refer to Chapter 26 "FLOODPLAIN, STORMWATER AND EROSION HAZARD MANAGEMENT" for additional information):

1. All work shall conform to the subject project Grading Plan included in the Development Package #D09-0011, which is made part of this permit (See Detail S/10 for additional information).
2. The required depth of the retaining wall footing shall be determined by the soils engineer, but shall not be less than 3'.
3. The disturbed soil, around, underneath and behind the proposed structures, shall be treated based on the geotechnical engineer recommendations and shall be compacted to least 95% density.
4. The existing drainage patterns shall not be obstructed or diverted other than what is shown on the attached approved grading plan.
5. Within 5 (five) days of issuance of this permit, through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "Construction proceeding under requirements of City of Tucson Floodplain Use Permit No. T09OT01100. For more information please call 791-5550."
6. Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.
7. This permit becomes invalid and is subject to additional floodplain review, if any required development permit (s') changes the configuration of the structure and or site development.

This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions set forth in this permit are not complied with. Also, this permit will expire one year from its date of issue. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division.

(EXPIRATION DATE) Month: 06 Day: 17 Year: 2010
APPLICANT NAME: Rick Engineering
ADDRESS: 3945 East Fort Lowell Road, Suite 111, Tucson, AZ 85712
PHONE NO.: (520) 795-1000


________________________ _____________

APPLICANT'S SIGNATURE DATE

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.

Final Status

Task End Date Reviewer's Name Type of Review Description
08/05/2009 SUE REEVES APPROVAL SHELF Completed
08/05/2009 CPIERCE1 OUT TO CUSTOMER Completed