Permit Number: T09OT00393
Parcel: 126120100

Review Status: Active

Review Details: FLOODPLAIN

Permit Number - T09OT00393
Review Name: FLOODPLAIN
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
02/26/2009 JASON GREEN ENGINEERING REVIEW Approved February 26, 2009
FLOODPLAIN USE PERMIT # T08OT00393
PROJECT ADDRESS: 340 N Belvedere Ave
APPLICANT'S NAME: Horatio Garcia
PROPERTY OWNER: Horatio Garcia

The applicant is authorized to use a portion of the City of Tucson Flood Hazard Area per the Midway Wash delineation, specifically described as:

340 N Belvedere Avenue in a portion of Township 14 South, Range 14 East, Sections 10, for the purpose of constructing approximately 55 LF CMU wall 6-foot high as shown on the site plan T09BU00291.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

The following 8 conditions apply to this permit:
1) This permit becomes invalid and is subject to additional floodplain review, if any required development changes the configuration of the approved site plan, or if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from constructing the proposed CMU Wall within the mapped regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson.
2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.
3) Drainage openings are required in the bottom 12-inches of the new wall every 10-feet off center to prevent hydrostatic pressure and blockage of onsite and offsite flows.
4) All work shall conform to the approved Details and site plan sheets, which are made part of this permit.
5) This permit is for the replacement of an existing CMU wall to have a 0-foot offset form the property line. No wall is allowed to be built within the back portion of the property under this permit. Any new wall will require a separate Floodplain Use Permit and Compliance Permit along with Civil Engineering calculations for floodplain encroachment or flow through opening design.
6) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T09OT00393 FOR INFORMATION PLEASE CALL 791-5550."
7) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times.
8) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval.

This Floodplain Use Permit will be automatically revoked and becomes invalid for non-compliance to conditions set forth in this permit. Also, this permit will expire one year from its date of issue. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division.

APPLICANT/CONTRACTOR: Horatio Garcia
ADDRESS: 4511 E 7th Street, Tucson, Arizona 85711
PHONE: (520) 322-0063
OWNER: Horatio Garcia
ADDRESS: 4511 E 7th Street, Tucson, Arizona 85711
PHONE: (520) 322-0063
(EXPIRATION DATE) Month: 07 Day: 26 Year: 2010

SIGNATURE OF APPLICANT DATE

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.