Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: FLOODPLAIN
Permit Number - T09OT00286
Review Name: FLOODPLAIN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/05/2009 | JASON GREEN | ENGINEERING | REVIEW | Approved | May 5, 2009 FLOODPLAIN USE PERMIT NO.: T09OT00286 ADDRESS: 310 S Williams Blvd #325 Tucson, Arizona 85711 PROPERTY OWNER: QuickTrip #1453 Attn: Mike Wooten 310 S Williams Blvd #325 Tucson, Arizona 85711 The applicant is authorized to use a portion of the City of Tucson Flood Hazard Area per the submitted Drainage Report prepared by DOWL HKM dated 09FEB09, specifically described as: A portion of Parcel 131-01-023B, CRAYCROFT TERRACE E115' OF LOT 1 & N250' S295' W175' E250' SE4 NE4 1.52 AC SEC 23-14-14 For the purpose of site grading, installation of a storm drain system into a public storm drain system, vehicular use area and any other improvements as shown on the approved Development Plan Package (D08-0047). The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit. The following 9 conditions apply to this permit: 1) This permit becomes invalid and is subject to additional floodplain review, if any required development changes the proposed disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from the site grading and storm drain connection within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson. 2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 3) The Drainage Report (DOWL HKM, 09FEB09) submitted for this project was reviewed and approved by the City of Tucson Development Services Engineering Administrator. All requirements within the report have been reviewed and found to be satisfactory with Development Services Engineering Section. 4) All work shall conform to the approved Details, development plan documents and the submitted Drainage Report for the site grading and drainage infrastructure, which are made part of this permit. 5) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T09OT0086 FOR INFORMATION PLEASE CALL 791-5550." 6) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times. 7) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval. 8) See the associated activity D08-0047. 9) This permit is specific to the improvements for 1884 S Craycroft Road as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division. This permit may be renewed for up to one year, in the absence of Registered Plant authorization, at the sole discretion of the City Engineer or designated representatives. This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit. APPLICANT NAME: QuikTrip Attn: Mike Wooten ADDRESS: 310 S Williams Blvd #325 Tucson, Arizona 85711 PHONE: 520-519-7346 CONTRACTOR: QuikTrip Attn: Mike Wooten ADDRESS: 310 S Williams Blvd #325 Tucson, Arizona 85711 PHONE: 520-519-7346 (EXPIRATION DATE) Month: _05 Day: 05 Year: 2010 SIGNATURE OF APPLICANT DATE The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/12/2009 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |