Permit Number - T09OT00190
Review Name: FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/29/2009 BIANCA RAMIREZ ENGINEERING REVIEW Approved Shed to be built in a manner to prevent floatation, collapse, and lateral movement.
2. Shed must be used solely for storage, parking of vehicles, and/or building access.
3. No electrical is to service shed.
4. No machinery and equipment which service a building such as furnaces, air conditioners, heat pumps, hot water heaters, washers, dryers, elevator lift equipment, electrical junction and circuit breaker boxes, and food freezers are permitted.
5. Shed to have a minimum of two openings installed with a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided.
a. The bottom of all openings shall be no higher than one foot above grade.
b. Openings may be equipped with screens, louvers, valves or other coverings or devices provided that they permit the automatic entry and exit of floodwaters.
6. Within 10 days after construction has been completed, the applicant must contact the District to verify all the requirements have been met. Please call (928) 771-3197 for final inspection.