Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T09OT00041
Parcel: 106101650

Review Status: Completed

Review Details: FLOODPLAIN

Permit Number - T09OT00041
Review Name: FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/08/2009 BIANCA RAMIREZ ENGINEERING REVIEW Approved Awaiting fence permit
01/08/2009 BIANCA RAMIREZ ENGINEERING REVIEW Approved Associated with T08BU00070.

January 12, 2009
FLOODPLAIN USE PERMIT NO.: T09OT00041
ADDRESS: 3920 N Sun Tran Blvd, Tucson Arizona 85705
PROPERTY OWNER: City of Tucson
4004 S Park Ave, Tucson AZ 85714

The applicant is authorized to use a portion of the FEMA Special Flood Hazard Area Zone AO1 per the Flood Insurance Rate Maps 04019C1619K, specifically described as:

A portion of Parcel 106-10-013B, CTRL PTN S2 NW4 LYG E & ADJ RD & FREEWAY AIRPORT INDUSTRIAL LOTS 1 THRU 8 19.50 AC FW 19.50 AC SEC 27-13-13
For the purpose of installation of chain link fence per the plan and attached detail.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard Area Regulations, and is bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations require application for, review and approval of an additional Floodplain Use Permit.

The following 8 conditions apply to this permit:

1) This permit becomes invalid and is subject to additional floodplain review, if any required development changes the configuration of the chain link fence installation, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from the construction of a shed within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson.
2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.
3) All work shall conform to the approved Details and General site plan sheets for the installation of the chain link fence, which are made part of this permit.
4) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T09OT00041 FOR INFORMATION PLEASE CALL 791-5550."
5) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times.
6) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval.
7) See the associated activity T08BU00070
8) This permit is specific to the improvements for 3920 N Sun Tran Blvd as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit.

This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit.

APPLICANT NAME: RB Woodruff
ADDRESS: 4004 S Park Ave, Tucson, AZ 85714
PHONE: 520-349-2113
CONTRACTOR: DL Withers
ADDRESS: 3220 E Harbour Dr Phoenix, AZ 85034
PHONE: 520-884-1114

(EXPIRATION DATE) Month: 01 Day: 13 Year: 2009

SIGNATURE OF APPLICANT DATE

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.

Final Status

Task End Date Reviewer's Name Type of Review Description
01/12/2009 CPIERCE1 OUT TO CUSTOMER Completed